Brahma Ignition transformer TC2STPAF 15910555
SKU 15910555
Model TC2STPAF
Brand Brahma
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 24 kV |
| Poles / outlets | 2 |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Standard power cable length | 560 mm |
| Recommended spark distance | 3–5 mm |
| Rated current (mA) | 27 mA |
| Output voltage frequency | 10 kHz |
| Protection class (IP) | IP00 |
| Peak current (mA) | 55 mA |
| Working cycle duration | 50% |
| Built-in filter | available |
| Compact size | yes |
| High efficiency | yes |
| Mounting and connecting systems | various |
| Short-circuit protection | built-in |
| High voltage cables placement | various options |
| Operating principle | high-frequency electronic generator |
| Ferritic core | yes |
| Varistor protection | built-in varistor |
| Compatible components | Brahma controllers |
| Mounting screw | M4x45 |
| Low voltage directive | 73/23/EEC |
| Output voltage max | 15 kV |
| Electromagnetic interference protection | filter to reduce electromagnetic interference |
| External filter not required | yes |
| Voltage fluctuation resistance | varistor |
| Secondary current | 55 mA |
| Duty cycle | 50% |
| Net weight | 0.42 kg |
| Power consumption | yes |
| Frequency | 50 Hz |
67.88 EUR
61.71EUR
in stock · 1
incl. 21% VAT · 51.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma Ignition transformer TC2STPAF 15910555 is a compact high-frequency electronic generator used in gas and liquid fuel burners. It operates on a 220–240 V supply at 50 Hz, producing a secondary voltage of 24 kV with a peak current of 55 mA and a rated current of 27 mA. The transformer features a ferritic core, built-in varistor protection, and a filter to reduce electromagnetic interference, eliminating the need for an external filter. It has a duty cycle of 50%, a recommended spark distance of 3–5 mm, and supports an ignition cable up to 1.5 m. The unit weighs 0.42 kg and is rated IP00.
Further details
| Application scope | gas and liquid fuel burners, including domestic, commercial and industrial installations |
|---|---|
| IMQ resolution | EN 61558-1:1997 + A1:1998 +A11:2003 and EN 61558-2-3:2000 |
| Protection against temperature fluctuations | special composition with high thermal conductivity and special expansion coefficient |
| Single or double-pin high voltage output | one- or two-pin high voltage output |
| Standards | EN 61558-1:1997 + A1:1998 +A11:2003 and EN 61558-2-3:2000 |
| Thermal compound | special composition with high thermal conductivity and special expansion coefficient |
Choosing and fitting
When selecting an ignition transformer of this type, ensure the supply voltage, frequency, and output voltage match the burner's requirements. The mounting system and connection options must be compatible with the existing controller and cabling. Verify the spark distance and cable length limits to ensure proper installation. The transformer can be mounted using M4x45 screws and is designed to work with compatible controllers.
Signs of failure
Common failures in ignition transformers include short circuits, voltage surges, and overheating, which may result in no spark or intermittent ignition. If the burner fails to ignite, check the transformer's output voltage and current, inspect the spark electrodes for proper gap, and verify the integrity of the high-voltage cable. A built-in varistor protects against voltage fluctuations, but repeated surges can damage the unit.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 24 kV |
| Poles / outlets | 2 |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Standard power cable length | 560 mm |
| Recommended spark distance | 3–5 mm |
| Rated current (mA) | 27 mA |
| Output voltage frequency | 10 kHz |
| Protection class (IP) | IP00 |
| Peak current (mA) | 55 mA |
| Working cycle duration | 50% |
| Built-in filter | available |
| Compact size | yes |
| High efficiency | yes |
| Mounting and connecting systems | various |
| Short-circuit protection | built-in |
| High voltage cables placement | various options |
| Operating principle | high-frequency electronic generator |
| Ferritic core | yes |
| Varistor protection | built-in varistor |
| Compatible components | Brahma controllers |
| Mounting screw | M4x45 |
| Low voltage directive | 73/23/EEC |
| Output voltage max | 15 kV |
| Electromagnetic interference protection | filter to reduce electromagnetic interference |
| External filter not required | yes |
| Voltage fluctuation resistance | varistor |
| Secondary current | 55 mA |
| Duty cycle | 50% |
| Net weight | 0.42 kg |
| Power consumption | yes |
| Frequency | 50 Hz |
Part numbers
| SKU | 15910555 |
|---|---|
| Additional article | 246.820.030 |
| Model | TC2STPAF |