Brahma Ignition transformer TC2SVCA 15911152
SKU 15911152
Model TC2SVCA
Brand Brahma
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 12–12 kV |
| Poles / outlets | 2 |
| Construction type | electronic, high-frequency |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 560 mm |
| Output voltage frequency | 10 kHz |
| Protection | IP00 |
| Number of contacts | 2 |
| Short-circuit protection | built-in |
| Ferritic core | ferritic core |
| High-frequency generator | high-frequency electronic generator |
| Mounting and connecting systems | various mounting and connecting systems |
| Complies with directive | 2004/108/ec |
| Operating principle | step-up transformer |
| Technology | high-frequency electronic generator |
| Installation type | directly on the transformer |
| Light weight | light weight |
| Compact size | compact size |
| High efficiency | high efficiency |
| Voltage fluctuation resistance | built-in varistor |
| Electromagnetic interference protection | filter to reduce electromagnetic interference |
| External filter not required | not required |
| Safety feature | built-in short circuit protection |
| Design features | compact design |
| Protection against moisture, vibration, overheating | special compound |
| Electrical insulation | special compound |
| Winding insulation | special compound |
| Core material | ferritic |
| Input voltage range | 220-240 V |
| Function | step-up transformer |
| Ingress protection | IP00 |
| Peak current (mA) | 55 mA |
| Built-in filter | integrated emc filter |
| Varistor protection | built-in varistor |
| Operating mode | continuous |
| Compact design | compact size |
| Compatible components | Brahma controllers |
| Operation mode | continuous |
| Device type | ignition transformer |
| Mounting type | directly on the transformer |
| Custom cable options | integrated power cable or connector |
| Energy efficiency | high efficiency |
| Number of outputs | 2 |
| High voltage outputs | 2 |
| EMC filter standard | 2004/108/ec |
| Protection against temperature fluctuations | special compound |
| Suitable for gas, diesel, oil | gas and liquid fuel burners |
| Transformer type | high-voltage transformer with ferritic core |
| Installation ease | compact size |
| Power supply | 220-240 V |
| Short name | Brahma 15911152 TC2SVCA ignition transformer |
| Name (English) | Brahma 15911152 TC2SVCA ignition transformer |
| SKU (English) | 15911152, 246.820.015 |
| Reliable ignition | efficient ignition |
| Recommended electrode distance | 3-5 mm |
| High discharge power | high power |
| Application scope | gas and liquid fuel burners |
| Working with | Brahma controllers |
| Low voltage directive | 73/23/eec |
| Mounting systems variety | various mounting and connecting systems |
| Number of poles | 2 |
| Varistor protection | built-in varistor |
| Interference reduction | filter to reduce electromagnetic interference |
| Output voltage max | 15 kV |
| Power cable options | integrated power cable or connector |
| Energy consumption | 55 VA |
| Weight (approx) | about 420 g |
| Power connection | integrated power cable or connector |
| Continuous operation | continuous |
| Compatible controllers | Brahma controllers |
| Protection class (IP) | IP00 |
| Fuel | gas and liquid fuel |
| Ignition system type | high-frequency electronic generator |
| Application | gas and liquid fuel burners |
| Secondary current | 55 mA |
| Duty cycle | 100% |
| Net weight | 0.42 kg |
| Power consumption | 55 W |
| Frequency | 50 Hz |
67.88 EUR
61.71EUR
in stock · 2
incl. 21% VAT · 51.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma TC2SVCA ignition transformer (SKU 15911152) is an electronic, high-frequency step-up transformer with a ferritic core, designed for gas and liquid fuel burners. It operates on a 220–240 V supply at 50 Hz, consuming 55 W, and delivers a secondary voltage of 12–12 kV with a secondary current of 55 mA at a frequency of 10 kHz. The transformer features a 100% duty cycle, two high-voltage outputs, and built-in short-circuit protection and a varistor for voltage fluctuation resistance. It includes an integrated EMC filter to reduce electromagnetic interference, complies with directive 2004/108/EC, and has an IP00 protection rating. The unit weighs 0.42 kg, has a compact design, and is suitable for continuous operation with Brahma controllers.
Further details
| Certification | EN 61558-1:1997 + A1:1998 +A11:2003 and EN 61558-2-3:2000 |
|---|---|
| Connector Availability | all connectors, including cable connectors, available on request |
| High Temperature Resistance | special compound with high thermal conductivity |
| Imq Resolution | EN 61558-1:1997 + A1:1998 +A11:2003 and EN 61558-2-3:2000 |
| Output Configuration | single or double-pin high voltage output |
| Protection Against Temperature Fluctuations | special compound with high thermal conductivity and unique expansion coefficient |
| Safety Standard | EN 61558-1:1997 + A1:1998 +A11:2003 and EN 61558-2-3:2000 |
| Single Or Double Contact | single or double-pin high voltage output |
| Standards | EN 61558-1:1997 + A1:1998 +A11:2003 and EN 61558-2-3:2000 |
| Thermal Compound | special compound with high thermal conductivity |
Choosing and fitting
When selecting a replacement ignition transformer of this type, ensure the supply voltage, frequency, and power consumption match the burner's electrical system. Verify the secondary voltage and current ratings, as well as the number of high-voltage outputs (single or double) and the type of high-voltage connection (threaded or Ø4 mm connector). The transformer must be compatible with the controller and mounting system; check the mounting dimensions and available connecting systems. Also confirm the maximum ignition cable length and recommended spark distance to ensure proper installation.
Signs of failure
Common failures in ignition transformers of this kind include short circuits or open circuits in the secondary winding, leading to weak or no spark. Overheating due to prolonged operation or inadequate cooling can cause insulation breakdown, resulting in intermittent ignition or complete failure. Voltage surges may damage the internal varistor or electronic components, causing erratic operation. Symptoms on the equipment include failure to ignite, delayed ignition, or burner lockout. Check the transformer for visible damage, measure secondary voltage with a suitable probe, and verify the spark gap and cable integrity.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 12–12 kV |
| Poles / outlets | 2 |
| Construction type | electronic, high-frequency |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 560 mm |
| Output voltage frequency | 10 kHz |
| Protection | IP00 |
| Number of contacts | 2 |
| Short-circuit protection | built-in |
| Ferritic core | ferritic core |
| High-frequency generator | high-frequency electronic generator |
| Mounting and connecting systems | various mounting and connecting systems |
| Complies with directive | 2004/108/ec |
| Operating principle | step-up transformer |
| Technology | high-frequency electronic generator |
| Installation type | directly on the transformer |
| Light weight | light weight |
| Compact size | compact size |
| High efficiency | high efficiency |
| Voltage fluctuation resistance | built-in varistor |
| Electromagnetic interference protection | filter to reduce electromagnetic interference |
| External filter not required | not required |
| Safety feature | built-in short circuit protection |
| Design features | compact design |
| Protection against moisture, vibration, overheating | special compound |
| Electrical insulation | special compound |
| Winding insulation | special compound |
| Core material | ferritic |
| Input voltage range | 220-240 V |
| Function | step-up transformer |
| Ingress protection | IP00 |
| Peak current (mA) | 55 mA |
| Built-in filter | integrated emc filter |
| Varistor protection | built-in varistor |
| Operating mode | continuous |
| Compact design | compact size |
| Compatible components | Brahma controllers |
| Operation mode | continuous |
| Device type | ignition transformer |
| Mounting type | directly on the transformer |
| Custom cable options | integrated power cable or connector |
| Energy efficiency | high efficiency |
| Number of outputs | 2 |
| High voltage outputs | 2 |
| EMC filter standard | 2004/108/ec |
| Protection against temperature fluctuations | special compound |
| Suitable for gas, diesel, oil | gas and liquid fuel burners |
| Transformer type | high-voltage transformer with ferritic core |
| Installation ease | compact size |
| Power supply | 220-240 V |
| Short name | Brahma 15911152 TC2SVCA ignition transformer |
| Name (English) | Brahma 15911152 TC2SVCA ignition transformer |
| SKU (English) | 15911152, 246.820.015 |
| Reliable ignition | efficient ignition |
| Recommended electrode distance | 3-5 mm |
| High discharge power | high power |
| Application scope | gas and liquid fuel burners |
| Working with | Brahma controllers |
| Low voltage directive | 73/23/eec |
| Mounting systems variety | various mounting and connecting systems |
| Number of poles | 2 |
| Varistor protection | built-in varistor |
| Interference reduction | filter to reduce electromagnetic interference |
| Output voltage max | 15 kV |
| Power cable options | integrated power cable or connector |
| Energy consumption | 55 VA |
| Weight (approx) | about 420 g |
| Power connection | integrated power cable or connector |
| Continuous operation | continuous |
| Compatible controllers | Brahma controllers |
| Protection class (IP) | IP00 |
| Fuel | gas and liquid fuel |
| Ignition system type | high-frequency electronic generator |
| Application | gas and liquid fuel burners |
| Secondary current | 55 mA |
| Duty cycle | 100% |
| Net weight | 0.42 kg |
| Power consumption | 55 W |
| Frequency | 50 Hz |
Part numbers
| SKU | 15911152 |
|---|---|
| Additional article | 246.820.015 |
| Model | TC2SVCA |