Brahma Ignition transformer TCD1BA 15930000
SKU 15930000
Model TCD1BA
Brand Brahma
Photos
Key specifications
| Supply voltage | 50–60 V |
|---|---|
| Secondary voltage | 6 kV |
| Poles / outlets | 1 |
| Construction type | compact dimensions and low weight |
| Protection class (IP) | IP00 |
| Core material | ferritic core |
| Complies with directive | 2004/108/ec |
| Low voltage directive | 2006/95/ec |
| IMQ resolution | en 61558-1:2005+a1:2009 and en 61558-2-3:2010 |
| Dimensional series compatibility | tc and td series |
| High efficiency | yes |
| Mounting and connecting systems | various |
| Operating principle | high-frequency electronic generator |
| Installation position | any |
| Number of contacts | 1 |
| Rated current (mA) | 37 mA |
| Output voltage frequency | 13 kHz |
| Protection | IP00 |
| Recommended spark distance | 3–5 mm |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Weight | about 250 |
| Peak voltage | 17 kV |
| Peak current (mA) | 83 mA |
| Built-in filter | yes |
| Output type | single or double-pin |
| Short-circuit protection | built-in |
| Varistor protection | built-in varistor |
| Application scope | domestic, commercial, industrial installations |
| Secondary current | 37 mA |
| Duty cycle | 33 |
| Net weight | 0.25 kg |
| Power consumption | yes |
| Frequency | 50 Hz |
67.88 EUR
61.71EUR
in stock · 2
incl. 21% VAT · 51.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma TCD1BA ignition transformer (SKU 15930000) is a compact, high-frequency electronic generator designed for gas and liquid fuel burners in domestic, commercial, and industrial installations. It operates at a supply voltage of 230 V and 50 Hz, producing a secondary voltage of 6 kV with a peak output of 17 kV. The transformer delivers a rated current of 37 mA and a peak current of 83 mA, with an output frequency of 13 kHz. It features a ferritic core, built-in EMC filter, short-circuit protection, and varistor protection, and complies with directives 2004/108/EC and 2006/95/EC. The unit has a duty cycle of 33%, weighs approximately 0.25 kg, and is rated IP00.
Further details
| Application | gas burners, light and heavy liquid fuel burners |
|---|---|
| Connection Type | triangular connector sp1 or connector 6.35x0.8 |
| Connector availability | all connectors, including connectors with cable, are available on request |
| Custom cable options | cable length and end can be changed on request |
| Grounding requirement | valve body must be connected to ground |
| Interchangeability | replace most transformers from other manufacturers |
| Overload Protection | protection against temperature fluctuations and overloads |
| Power connector options | triangular connector sp1 or connector 6.35x0.8 |
| Replacement capability | replace most transformers from other manufacturers |
| Thermal Compound | special composition with high thermal conductivity and a special expansion coefficient |
| Thermal protection | special composition with high thermal conductivity and expansion coefficient |
| Varistor | built-in varistor protects against power surges |
Choosing and fitting
When selecting an ignition transformer of this type, ensure the supply voltage, frequency, and output voltage match the burner controller's requirements. The transformer must have the correct mounting configuration and connector type (e.g., triangular SP1 or 6.35x0.8) to fit the existing wiring. Verify the high-voltage output connection (Ø4 mm connector or threaded) and the maximum ignition cable length (1.5 m) to ensure compatibility. Installation can be in any position, but high-voltage cables must be kept away from other cables, and the valve body must be grounded for safety.
Signs of failure
Typical failures of ignition transformers include internal short circuits or open windings, often caused by overheating or voltage surges. Symptoms may include no spark at the electrode, weak or intermittent ignition, or burner lockout. Check for visible damage, measure the secondary voltage with a suitable probe, and verify the primary supply voltage and ground connection. A built-in varistor protects against surges, but repeated overvoltage can still damage the unit.
All specifications
| Supply voltage | 50–60 V |
|---|---|
| Secondary voltage | 6 kV |
| Poles / outlets | 1 |
| Construction type | compact dimensions and low weight |
| Protection class (IP) | IP00 |
| Core material | ferritic core |
| Complies with directive | 2004/108/ec |
| Low voltage directive | 2006/95/ec |
| IMQ resolution | en 61558-1:2005+a1:2009 and en 61558-2-3:2010 |
| Dimensional series compatibility | tc and td series |
| High efficiency | yes |
| Mounting and connecting systems | various |
| Operating principle | high-frequency electronic generator |
| Installation position | any |
| Number of contacts | 1 |
| Rated current (mA) | 37 mA |
| Output voltage frequency | 13 kHz |
| Protection | IP00 |
| Recommended spark distance | 3–5 mm |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Weight | about 250 |
| Peak voltage | 17 kV |
| Peak current (mA) | 83 mA |
| Built-in filter | yes |
| Output type | single or double-pin |
| Short-circuit protection | built-in |
| Varistor protection | built-in varistor |
| Application scope | domestic, commercial, industrial installations |
| Secondary current | 37 mA |
| Duty cycle | 33 |
| Net weight | 0.25 kg |
| Power consumption | yes |
| Frequency | 50 Hz |
Part numbers
| SKU | 15930000 |
|---|---|
| Additional article | 246.820.046 |
| Model | TCD1BA |