Brahma Ignition transformer TCD1BA 15930000

SKU 15930000 Model TCD1BA Brand Brahma

Photos

Key specifications

Supply voltage50–60 V
Secondary voltage6 kV
Poles / outlets1
Construction typecompact dimensions and low weight
Protection class (IP)IP00
Core materialferritic core
Complies with directive2004/108/ec
Low voltage directive2006/95/ec
IMQ resolutionen 61558-1:2005+a1:2009 and en 61558-2-3:2010
Dimensional series compatibilitytc and td series
High efficiencyyes
Mounting and connecting systemsvarious
Operating principlehigh-frequency electronic generator
Installation positionany
Number of contacts1
Rated current (mA)37 mA
Output voltage frequency13 kHz
ProtectionIP00
Recommended spark distance3–5 mm
Maximum length of ignition cable with integrated electronic ignition1.5 m
Weightabout 250
Peak voltage17 kV
Peak current (mA)83 mA
Built-in filteryes
Output typesingle or double-pin
Short-circuit protectionbuilt-in
Varistor protectionbuilt-in varistor
Application scopedomestic, commercial, industrial installations
Secondary current37 mA
Duty cycle33
Net weight0.25 kg
Power consumptionyes
Frequency50 Hz
all specifications (33) ↓
67.88 EUR
61.71EUR
in stock · 2

incl. 21% VAT · 51.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma TCD1BA ignition transformer (SKU 15930000) is a compact, high-frequency electronic generator designed for gas and liquid fuel burners in domestic, commercial, and industrial installations. It operates at a supply voltage of 230 V and 50 Hz, producing a secondary voltage of 6 kV with a peak output of 17 kV. The transformer delivers a rated current of 37 mA and a peak current of 83 mA, with an output frequency of 13 kHz. It features a ferritic core, built-in EMC filter, short-circuit protection, and varistor protection, and complies with directives 2004/108/EC and 2006/95/EC. The unit has a duty cycle of 33%, weighs approximately 0.25 kg, and is rated IP00.

Further details

Applicationgas burners, light and heavy liquid fuel burners
Connection Typetriangular connector sp1 or connector 6.35x0.8
Connector availabilityall connectors, including connectors with cable, are available on request
Custom cable optionscable length and end can be changed on request
Grounding requirementvalve body must be connected to ground
Interchangeabilityreplace most transformers from other manufacturers
Overload Protectionprotection against temperature fluctuations and overloads
Power connector optionstriangular connector sp1 or connector 6.35x0.8
Replacement capabilityreplace most transformers from other manufacturers
Thermal Compoundspecial composition with high thermal conductivity and a special expansion coefficient
Thermal protectionspecial composition with high thermal conductivity and expansion coefficient
Varistorbuilt-in varistor protects against power surges

Choosing and fitting

When selecting an ignition transformer of this type, ensure the supply voltage, frequency, and output voltage match the burner controller's requirements. The transformer must have the correct mounting configuration and connector type (e.g., triangular SP1 or 6.35x0.8) to fit the existing wiring. Verify the high-voltage output connection (Ø4 mm connector or threaded) and the maximum ignition cable length (1.5 m) to ensure compatibility. Installation can be in any position, but high-voltage cables must be kept away from other cables, and the valve body must be grounded for safety.

Signs of failure

Typical failures of ignition transformers include internal short circuits or open windings, often caused by overheating or voltage surges. Symptoms may include no spark at the electrode, weak or intermittent ignition, or burner lockout. Check for visible damage, measure the secondary voltage with a suitable probe, and verify the primary supply voltage and ground connection. A built-in varistor protects against surges, but repeated overvoltage can still damage the unit.

All specifications

Supply voltage50–60 V
Secondary voltage6 kV
Poles / outlets1
Construction typecompact dimensions and low weight
Protection class (IP)IP00
Core materialferritic core
Complies with directive2004/108/ec
Low voltage directive2006/95/ec
IMQ resolutionen 61558-1:2005+a1:2009 and en 61558-2-3:2010
Dimensional series compatibilitytc and td series
High efficiencyyes
Mounting and connecting systemsvarious
Operating principlehigh-frequency electronic generator
Installation positionany
Number of contacts1
Rated current (mA)37 mA
Output voltage frequency13 kHz
ProtectionIP00
Recommended spark distance3–5 mm
Maximum length of ignition cable with integrated electronic ignition1.5 m
Weightabout 250
Peak voltage17 kV
Peak current (mA)83 mA
Built-in filteryes
Output typesingle or double-pin
Short-circuit protectionbuilt-in
Varistor protectionbuilt-in varistor
Application scopedomestic, commercial, industrial installations
Secondary current37 mA
Duty cycle33
Net weight0.25 kg
Power consumptionyes
Frequency50 Hz

Part numbers

SKU15930000
Additional article246.820.046
ModelTCD1BA