{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Brahma Ignition transformer TCD1FAV 15930023

SKU 15930023 Model TCD1FAV Brand Brahma

Photos

Key specifications

Supply voltage230 V
Secondary voltage6 kV
Poles / outlets1
Single or double-pin high voltage outputsingle or double-pin
Mounting and connecting systemsvarious
Short-circuit protectionbuilt-in
Operating principlehigh-frequency electronic generator
Ferritic coreyes
Maximum length of ignition cable with integrated electronic ignition1.5 m
Recommended spark distance3–5 mm
Peak current (mA)83 mA
ProtectionIP 00
Built-in filteryes
Dimensional series compatibilityTC and TD series
High efficiencyyes
Varistor protectionbuilt-in varistor
Connector availabilityavailable on request
Complies with directive2004/108/EC
Low voltage directive2006/95/EC
IMQ resolutionEN 61558-1:2005+A1:2009 and EN 61558-2-3:2010
Output voltage frequency13 kHz
Protection against temperature fluctuationsspecial composition
Compact designextremely compact overall dimensions
Secondary current37 mA
Duty cycle33%
Net weight0.25 kg
Power consumptionyes
Frequency50 Hz
all specifications (28) ↓
price on request
on order

shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma Ignition transformer TCD1FAV (SKU 15930023) is a high-frequency electronic generator with a ferritic core, designed for gas and liquid fuel burners. It operates at a supply voltage of 230 V and 50 Hz, producing a secondary voltage of 6 kV with a secondary current of 37 mA. The transformer features a built-in short circuit protection, varistor protection, and an integrated filter, complying with directives 2004/108/EC and 2006/95/EC. It has a duty cycle of 33%, a peak current of 83 mA, and an output voltage frequency of 13 kHz. The device is compact, weighs 0.25 kg, and is compatible with Brahma TC and TD series, with a maximum ignition cable length of 1.5 m and a recommended spark distance of 3–5 mm.

Further details

Application scopegas burners, burners for light and heavy liquid fuels in domestic, commercial, industrial installations
Connector optionstriangular connector SP1 or connector 6.35x0.8
Interchangeabilityreplace most transformers from other manufacturers
Thermal compoundspecial composition with high thermal conductivity and special expansion coefficient

Choosing and fitting

When selecting an ignition transformer of this type, ensure the supply voltage, frequency, and secondary voltage match the burner's requirements. The mounting and connecting systems vary, so verify the physical dimensions and connector type (e.g., single or double-pin) against the existing unit. The transformer's dimensions are compatible with TC and TD series, but always compare the mounting holes and high-voltage output configuration. The ignition cable length and spark distance must be within the specified limits for proper operation.

Signs of failure

Typical failures of ignition transformers include short circuits, open circuits, or breakdown of the high-voltage insulation, often caused by moisture, overheating, or voltage surges. Symptoms on the equipment include no spark at the electrode, weak or intermittent sparking, or burner ignition failure. Check the primary and secondary circuits for continuity, inspect the high-voltage cable and connections for damage, and verify the spark gap is within the recommended range. If the transformer overheats or trips, inspect the duty cycle and ensure the cooling is adequate.

Fits equipment

Brahma TC and TD series

All specifications

Supply voltage230 V
Secondary voltage6 kV
Poles / outlets1
Single or double-pin high voltage outputsingle or double-pin
Mounting and connecting systemsvarious
Short-circuit protectionbuilt-in
Operating principlehigh-frequency electronic generator
Ferritic coreyes
Maximum length of ignition cable with integrated electronic ignition1.5 m
Recommended spark distance3–5 mm
Peak current (mA)83 mA
ProtectionIP 00
Built-in filteryes
Dimensional series compatibilityTC and TD series
High efficiencyyes
Varistor protectionbuilt-in varistor
Connector availabilityavailable on request
Complies with directive2004/108/EC
Low voltage directive2006/95/EC
IMQ resolutionEN 61558-1:2005+A1:2009 and EN 61558-2-3:2010
Output voltage frequency13 kHz
Protection against temperature fluctuationsspecial composition
Compact designextremely compact overall dimensions
Secondary current37 mA
Duty cycle33%
Net weight0.25 kg
Power consumptionyes
Frequency50 Hz

Part numbers

SKU15930023
Additional article246.820.055
ModelTCD1FAV