Brahma Ignition transformer TD1LVCAF 15910408
SKU 15910408
Model TD1LVCAF
Brand Brahma
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 15 kV |
| Poles / outlets | 1 |
| Number of contacts | 1 |
| Peak voltage | 15 kV |
| Peak current (mA) | 45 mA |
| Rated current (mA) | 25 mA |
| Operating temperature | -10–60 °C |
| Recommended spark distance | 3–5 mm |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Protection | IP00 |
| Output voltage frequency | 6–10 kHz |
| Varistor protection | built-in |
| Mounting screw | M4x45 screws |
| Built-in filter | EMC filter |
| Complies with directive | 2004/108/EC |
| External filter not required | yes |
| Mounting and connecting systems | various fastening and connecting systems |
| High-frequency generator | yes |
| Compact size | yes |
| Operating phase | ignition phase |
| Output voltage max | 15 kV |
| Version | 10 Hz |
| Nominal current | 25 mA |
| Standard power cable length | 560 mm |
| Core material | ferritic core |
| Includes ignition cable | yes |
| Short-circuit protection | built-in |
| High efficiency | yes |
| Connector availability | available on request |
| Ferritic core | yes |
| Light weight | yes |
| Protection class (IP) | IP00 |
| Secondary current | 25 mA |
| Duty cycle | 50% |
| Net weight | 0.36 kg |
| Power consumption | 45 W |
| Frequency | 50–60 Hz |
—price on request
on order
shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma TD1LVCAF ignition transformer (SKU 15910408) is a high-frequency electronic generator with a ferritic core, designed for gas and liquid fuel burners in domestic, commercial, and industrial installations. It provides a peak output voltage of 15 kV and a rated secondary current of 25 mA, with a power consumption of 45 W. The transformer operates on a 220–240 V supply at 50–60 Hz, features a built-in varistor and EMC filter, and complies with directive 2004/108/EC. It has one high-voltage contact, a duty cycle of 50%, and an operating temperature range of -10 to 60 °C. The unit includes an ignition cable, weighs 0.36 kg, and is protected to IP00.
Further details
| Application Scope | gas burners and liquid fuel burners in domestic, commercial and industrial installations |
|---|---|
| Output voltage frequency (kHz) | 6 (No.1) and 10 (No. 2) |
| Protection | IP00 |
| Protection Against Temperature Fluctuations | special composition with high thermal conductivity and a special expansion coefficient |
| Single Or Double Contact | one- or two-pin high voltage output |
| Supply voltage | 220-240 V 50/60 Hz; on request: 110-120 V 50/60 Hz |
| Thermal Compound | special composition with high thermal conductivity and a special expansion coefficient |
| Weight | about 360 g |
Choosing and fitting
When selecting an ignition transformer of this type, ensure the supply voltage, frequency, and duty cycle match the burner's requirements. Verify the number of high-voltage contacts and the type of connection (e.g., threaded or Ø4 mm connector) to fit the existing ignition cable. The transformer must be mounted securely, often using M4x45 screws, and the ignition cable length should not exceed the specified maximum. Check the recommended spark distance and ensure the operating temperature range is suitable for the installation environment.
Signs of failure
Common failures in ignition transformers include short circuits or open circuits in the high-voltage output, which can result in weak or no spark. Overheating due to excessive duty cycle or poor ventilation may cause internal component damage, leading to intermittent ignition. A faulty varistor can fail to protect against power surges, potentially damaging the transformer. Symptoms include burner ignition failure, sparking at the cable or connections, or a buzzing sound from the transformer. Check the ignition cable for damage, verify the spark gap, and test the transformer's output voltage with a suitable meter.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 15 kV |
| Poles / outlets | 1 |
| Number of contacts | 1 |
| Peak voltage | 15 kV |
| Peak current (mA) | 45 mA |
| Rated current (mA) | 25 mA |
| Operating temperature | -10–60 °C |
| Recommended spark distance | 3–5 mm |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Protection | IP00 |
| Output voltage frequency | 6–10 kHz |
| Varistor protection | built-in |
| Mounting screw | M4x45 screws |
| Built-in filter | EMC filter |
| Complies with directive | 2004/108/EC |
| External filter not required | yes |
| Mounting and connecting systems | various fastening and connecting systems |
| High-frequency generator | yes |
| Compact size | yes |
| Operating phase | ignition phase |
| Output voltage max | 15 kV |
| Version | 10 Hz |
| Nominal current | 25 mA |
| Standard power cable length | 560 mm |
| Core material | ferritic core |
| Includes ignition cable | yes |
| Short-circuit protection | built-in |
| High efficiency | yes |
| Connector availability | available on request |
| Ferritic core | yes |
| Light weight | yes |
| Protection class (IP) | IP00 |
| Secondary current | 25 mA |
| Duty cycle | 50% |
| Net weight | 0.36 kg |
| Power consumption | 45 W |
| Frequency | 50–60 Hz |
Part numbers
| SKU | 15910408 |
|---|---|
| Additional article | 246.820.080 |
| Model | TD1LVCAF |