Brahma Ignition transformer TD2STCS 15911360
SKU 15911360
Model TD2STCS
Brand Brahma
Photos
Key specifications
| Supply voltage | 110-120 V 50/60 Hz |
|---|---|
| Poles / outlets | 2 |
| Number of contacts | 2 |
| Peak voltage | 12 kV |
| Peak current (mA) | 55 mA |
| Output voltage frequency | 8.5–12 kHz |
| Ingress protection | IP00 |
| Recommended spark distance | 3–5 mm |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Standard power cable length | 560 mm |
| Safety feature | short circuit protection |
| Technology | high-frequency electronic generator |
| Core material | ferritic |
| Varistor protection | built-in |
| Built-in filter | optional |
| Electromagnetic interference protection | integrated EMC filter (optional) |
| Mounting feature | any position |
| Mounting and connecting systems | various mounting and connecting systems |
| Power connector | built-in power cable or connector |
| Catalogue article numbers | 246.820.123 |
| Fuel | gas and liquid fuels |
| Mounting screw | M4x45 |
| Grounding requirement | valve body connected to ground |
| Duty cycle | 100% |
| Net weight | 0.36 kg |
| Power consumption | 30 W |
| Frequency | 50–60 Hz |
67.88 EUR
61.71EUR
in stock · 5
incl. 21% VAT · 51.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This ignition transformer uses a high-frequency electronic generator with a ferritic core to produce the ignition spark for burners operating on gas or liquid fuel. It runs on 110–120 V AC at 50/60 Hz and draws 30 W, with a 100% duty cycle. The output is 12 kV peak at 55 mA, with a frequency range of 8.5–12 kHz. It has two poles and two contacts. Protection includes a built-in varistor and short-circuit protection. The unit is rated IP00, recommends an electrode gap of 3–5 mm, and allows an ignition cable up to 1.5 m; its standard power cable is 560 mm and net weight is 0.36 kg.
Further details
| Application | gas burners, light and heavy liquid fuels, domestic, commercial and industrial |
|---|---|
| Connector availability | connectors with cable available on request |
| Design Features | light weight and compact size; high efficiency and ignition power; low power consumption |
Choosing and fitting
Ignition transformers of this type are selected by supply voltage, number of high-voltage contacts, and high-voltage connection configuration (threaded or 4 mm connector). They may be supplied with a built-in power cable or a power connector, and with or without an integrated EMC filter. When installing a replacement, use the fixing method specified for the controller—for Brahma controllers, M4x45 screws are typical—and ensure the valve body is grounded. The transformer can be oriented in any position.
Fits equipment
Brahma controllers
All specifications
| Supply voltage | 110-120 V 50/60 Hz |
|---|---|
| Poles / outlets | 2 |
| Number of contacts | 2 |
| Peak voltage | 12 kV |
| Peak current (mA) | 55 mA |
| Output voltage frequency | 8.5–12 kHz |
| Ingress protection | IP00 |
| Recommended spark distance | 3–5 mm |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Standard power cable length | 560 mm |
| Safety feature | short circuit protection |
| Technology | high-frequency electronic generator |
| Core material | ferritic |
| Varistor protection | built-in |
| Built-in filter | optional |
| Electromagnetic interference protection | integrated EMC filter (optional) |
| Mounting feature | any position |
| Mounting and connecting systems | various mounting and connecting systems |
| Power connector | built-in power cable or connector |
| Catalogue article numbers | 246.820.123 |
| Fuel | gas and liquid fuels |
| Mounting screw | M4x45 |
| Grounding requirement | valve body connected to ground |
| Duty cycle | 100% |
| Net weight | 0.36 kg |
| Power consumption | 30 W |
| Frequency | 50–60 Hz |
Part numbers
| SKU | 15911360 |
|---|---|
| Additional article | 246.820.123 |
| Model | TD2STCS |