Cofi High-voltage ignition transformer TRE820
SKU TRE820
Brand Cofi
Photos
Key specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 8 kV |
| Length | 190 mm |
| Width | 130 mm |
| Height | 105 mm |
| Current | 0.9 A |
| Output configuration | 2x4 kV |
| Ignition cable insulation | armoured or silicone-insulated cable |
| Duty cycle | 20 % on 80 % off over a one-minute period |
| Net weight | 1.325 kg |
| Gross weight | 1.4 kg |
| Frequency | 50 Hz |
73.54 EUR
66.85EUR
in stock · 10
incl. 21% VAT · 55.25 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Cofi TRE820 is a high-voltage ignition transformer designed to generate a spark in automatic ignition systems of gas and diesel burners. It operates with a supply voltage of 230 V at 50 Hz, drawing a current of 0.9 A. The transformer provides a secondary voltage of 8 kV, configured as 2x4 kV outputs. It has dimensions of 190 mm in length, 130 mm in width, and 105 mm in height, with a net weight of 1.325 kg and a gross weight of 1.4 kg. The duty cycle is 20% on and 80% off over a one-minute period, and it is suitable for use with armoured or silicone-insulated ignition cables.
Further details
| Advantages | stable high voltage for reliable ignition, original cofi transformer, reliable operation in automatic ignition systems, high durability and resistance to loads, suitable for industrial and domestic equipment |
|---|---|
| Application | gas burners, diesel burners, dual-fuel burners, boiler equipment, automatic ignition systems |
| Maintenance requirement | cable condition must be verified during troubleshooting |
| Mounting feature | mounted on the burner chassis or inside the electrical enclosure |
| Operating phase | operates only during the ignition phase of the burner sequence, energised by a command from the burner control |
Choosing and fitting
When selecting a replacement ignition transformer of this type, ensure the primary voltage (typically 230 V or 110 V, with 24 V variants for certain installations), secondary voltage and current capacity, duty cycle rating, terminal arrangement, and the connector pattern for the high-voltage cable match the existing layout. Mounting dimensions and the type of high-voltage output (e.g., recessed spring contact vs. screw terminal) must also be compatible. Always check the condition of the ignition cable, as cracked or hardened silicone insulation can cause spark leakage.
Signs of failure
Common failure modes for ignition transformers include internal short circuits, open windings, or insulation breakdown, leading to weak or no spark at the electrodes. The burner may fail to ignite, lock out, or cycle repeatedly. Check the transformer for visible damage, measure primary and secondary voltages with appropriate safety precautions, and inspect the high-voltage cable and connections for wear or corrosion.
All specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 8 kV |
| Length | 190 mm |
| Width | 130 mm |
| Height | 105 mm |
| Current | 0.9 A |
| Output configuration | 2x4 kV |
| Ignition cable insulation | armoured or silicone-insulated cable |
| Duty cycle | 20 % on 80 % off over a one-minute period |
| Net weight | 1.325 kg |
| Gross weight | 1.4 kg |
| Frequency | 50 Hz |
Part numbers
| SKU | TRE820 |
|---|---|
| Additional article | 309.820.028 |