Cofi Ignition transformer TRE820P

SKU TRE820P Brand Cofi

Photos

Key specifications

Supply voltage230 V
Secondary voltage8 kV
Output type1x8 kV
Housing typecompact housing
Application scopegas and dual-fuel burners
Operating phaseonly during ignition period
Ignition cable insulationsilicone-insulated
Working withignition electrode and burner control
Frequency50 Hz
Country of originItaly
all specifications (10) ↓
87.40 EUR
79.45EUR
in stock · 2

incl. 21% VAT · 65.66 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Cofi TRE820P is a single-pole ignition transformer with a supply voltage of 230 V and a secondary voltage of 8 kV, operating at 50 Hz. It is designed for gas and dual-fuel burners, providing a high-voltage discharge to the ignition electrode during the ignition period. This transformer is housed in a compact enclosure and is compatible with burners from COFI, CIB Unigas, Riello, Ecoflam, and other brands. It is an OEM equivalent to the FIDA Compact 8/20PM P.

Further details

Advantagespowerful ignition, compact and durable housing, high reliability, easy installation
Applicationgas burners, industrial and domestic boiler houses, heat guns, dryers, baking and process equipment
Cable conditionhardened or cracked cable can leak spark to earth
Compatibility checkmatch primary voltage and duty cycle, check cable and terminal pattern
Replacementreplacement of analogue fida compact 8/20pm p
Safety timeif flame not confirmed within safety time, control locks out

Choosing and fitting

When selecting an ignition transformer of this type, verify that the primary voltage (e.g., 230 V) and frequency match the burner's supply, and that the secondary voltage and current rating are appropriate for the electrode gap. Check the mounting dimensions, terminal types, and high-voltage cable connector pattern to ensure compatibility with the existing wiring and electrode assembly. The transformer operates only during the ignition sequence, so the duty cycle must align with the burner control's safety time.

Signs of failure

Typical failures include no spark at the electrode, intermittent ignition, or a spark that leaks to ground due to cracked or hardened ignition cables. The burner may fail to light or lock out after the safety time if the transformer does not produce sufficient voltage. Check the transformer's primary voltage and secondary output with a suitable meter, and inspect the ignition cable for insulation damage before replacing the unit.

Fits equipment

multiple COFI, CIB Unigas, Riello, Ecoflam and many other brands of gas burnersCofi TRE820PCIB Unigas Riello Ecoflam

All specifications

Supply voltage230 V
Secondary voltage8 kV
Output type1x8 kV
Housing typecompact housing
Application scopegas and dual-fuel burners
Operating phaseonly during ignition period
Ignition cable insulationsilicone-insulated
Working withignition electrode and burner control
Frequency50 Hz
Country of originItaly

Part numbers

SKUTRE820P
Additional article309.820.015
OEM equivalentFIDA Compact 8/20PM P