Cofi Ignition transformer TRG1035/4

SKU TRG1035/4 Brand Cofi

Photos

Key specifications

Supply voltage220–230 V
Secondary voltage10 kV
Poles / outlets2
Length150 mm
Width87 mm
Height80 mm
Body materialdurable heat-resistant material
Catalogue article numbers309.820.084, TRG1035/4
Ingress protectionIP00
Ignition cable connectorø4 mm
Number of contacts2
Winding insulationepoxy resin
CertificationCEI EN 61558-2-3
Fuelgas and liquid fuel
Safety featureprotection against short circuits
Input voltage range220-230V
Secondary current35 mA
Duty cycle25% ED within 4 minutes
Net weight2.43 kg
Frequency50 Hz
Country of originItaly
all specifications (21) ↓
125.62 EUR
114.20EUR
in stock · 1

incl. 21% VAT · 94.38 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This ignition transformer steps up the supply voltage to create a spark for automatic burners. It operates from 220–230 V, 50 Hz and delivers 10 kV at 35 mA, with a duty cycle of 25% ED within 4 minutes and two poles. The body measures 150 x 87 x 80 mm and weighs 2.43 kg net. The housing is made of durable heat-resistant material, windings are insulated with epoxy resin, and ingress protection is IP00. It is intended for gas and liquid fuel burners and compatible with several major burner brands. This unit is made in Italy and certified to CEI EN 61558-2-3.

Further details

Applicationheating equipment, boilers and industrial plants
Design featuresresistant to voltage and temperature fluctuations

Choosing and fitting

Parts of this type are selected by secondary voltage and current, primary voltage, duty cycle, and physical mounting and terminal arrangement. The high-voltage cable connector pattern must match the transformer output and the electrode terminal. Before ordering, check the primary voltage and duty cycle of the burner's control sequence, and measure the mounting dimensions and terminal spacing. When installing, inspect the silicone-insulated ignition cable for hardening or cracks, and verify the electrode gap is within specification.

Signs of failure

No spark at the electrode and a subsequent burner lockout are the usual symptoms of a failed ignition transformer. However, the same symptoms can be caused by a hardened or cracked silicone ignition cable that leaks the spark to earth, or by an incorrect electrode gap. Therefore, inspect the cable and electrode gap before condemning the transformer.

Fits equipment

riello ecoflam fbr elco baltur lamborghini weishaupt giersch

All specifications

Supply voltage220–230 V
Secondary voltage10 kV
Poles / outlets2
Length150 mm
Width87 mm
Height80 mm
Body materialdurable heat-resistant material
Catalogue article numbers309.820.084, TRG1035/4
Ingress protectionIP00
Ignition cable connectorø4 mm
Number of contacts2
Winding insulationepoxy resin
CertificationCEI EN 61558-2-3
Fuelgas and liquid fuel
Safety featureprotection against short circuits
Input voltage range220-230V
Secondary current35 mA
Duty cycle25% ED within 4 minutes
Net weight2.43 kg
Frequency50 Hz
Country of originItaly

Part numbers

SKUTRG1035/4
Additional article309.820.084
OEM equivalentRiello
OEM equivalentEcoflam
OEM equivalentFBR
OEM equivalentElco
OEM equivalentBaltur
OEM equivalentLamborghini
OEM equivalentWeishaupt
OEM equivalentGiersch