Cofi Ignition transformer TRG1035/6

SKU TRG1035/6 Brand Cofi

Photos

Key specifications

Supply voltage230 V
Secondary voltage5 kV
Length107 mm
Width85 mm
Height80 mm
Output current1.9 A
Reliabilitylong service life
Design featurescompact dimensions for its class
Frequency50 Hz
all specifications (9) ↓
106.35 EUR
96.68EUR
in stock · 2

incl. 21% VAT · 79.90 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Cofi TRG1035/6 is an ignition transformer designed for high-power gas, diesel, and heavy fuel oil burners. It operates on a 230 V, 50 Hz supply and provides a secondary voltage of 5 kV with an output current of 1. 9 A. The transformer measures 107 mm in length, 85 mm in width, and 80 mm in height, featuring a compact design for its class. Its induction design ensures stable spark generation for burner start-up under intensive use.

Further details

Applicationgas burners, diesel burners, heavy fuel oil burners, boiler installations, industrial heat generators
Energizationenergised after the pre-purge phase and fuel admission begins
Flame detection methods supportedflame is proven by the ionisation electrode or uv/ir detector
Ignition cable insulationsilicone-insulated to withstand high voltage and heat
Installation easesimplify installation and replacement of standard equipment
Operating phaseoperates only during the ignition phase, as commanded by the burner control
Operating principlesteps up mains voltage to the level required to produce a spark at the ignition electrode gap
Replacement considerationsprimary voltage, secondary voltage and current, duty cycle, mounting style, terminal type, and cable connector pattern must match the existing installation
Replacement verificationa correctly matched transformer is essential for reliable ignition and safe burner operation
Troubleshootinga hardened or cracked cable can leak the spark to earth, which may be misinterpreted as a faulty transformer
Working withconnected between the burner control and the ignition electrode

Choosing and fitting

When selecting a replacement ignition transformer of this type, ensure the primary voltage, secondary voltage and current, duty cycle, mounting style, terminal type, and cable connector pattern match the existing installation. Common primary voltages include 230 V, 110 V, and 24 V. The secondary output must be sufficient to strike a spark under combustion chamber conditions. Check the condition of ignition cables, as hardened or cracked silicone insulation can leak the spark to earth, which may be misinterpreted as a faulty transformer.

Signs of failure

Typical failures of ignition transformers include internal short circuits, open windings, or insulation breakdown, leading to weak or no spark at the ignition electrode. Equipment may fail to ignite, causing burner lockout or repeated ignition attempts. Check for visible damage, listen for buzzing sounds, and measure primary and secondary voltages with a multimeter to diagnose. Also inspect ignition cables for cracks or hardening, as these can cause spark leakage and mimic transformer failure.

All specifications

Supply voltage230 V
Secondary voltage5 kV
Length107 mm
Width85 mm
Height80 mm
Output current1.9 A
Reliabilitylong service life
Design featurescompact dimensions for its class
Frequency50 Hz

Part numbers

SKUTRG1035/6
Additional article309.820.064