Cofi Ignition transformer TRG1230
SKU TRG1230
Brand Cofi
Photos
Key specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 14 kV |
| Poles / outlets | 2 |
| Length | 150 mm |
| Width | 87 mm |
| Height | 80 mm |
| Ignition cable insulation | silicone-insulated |
| Operating phase | ignition phase only |
| Dimensions | 150x87x80 mm |
| Number of outputs | 2 |
| High voltage outputs | 2 |
| Current consumption | 2.1–2.3 A |
| External package dimensions (LxWxH) | 190x130x105 |
| Energization | energised only during ignition phase |
| Net weight | 2.71 kg |
| Gross weight | 2.785 kg |
| Frequency | 50 Hz |
96.47 EUR
87.70EUR
in stock · 2
incl. 21% VAT · 72.48 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Cofi TRG1230 is an ignition transformer designed to generate a high-voltage spark for automatic ignition systems in gas and liquid fuel burners. It operates on a 230 V supply at 50 Hz, drawing 2.1–2.3 A, and provides two high-voltage outputs at 14 kV total (2 x 7 kV). The transformer is energised only during the ignition phase, as controlled by the burner control. Its dimensions are 150x87x80 mm, with a net weight of 2.71 kg and gross weight of 2.785 kg. The ignition cables are silicone-insulated to withstand high voltage and heat.
Further details
| Advantages | powerful spark formation, reliable operation, original product, suitable for gas and diesel burners, long service life, high reliability |
|---|---|
| Application | gas burners, diesel burners, combination burners, boiler equipment, industrial heat generators, automatic ignition systems |
| Cable condition check | inspect cable and connectors before condemning transformer |
| Replacement considerations | primary voltage, secondary voltage and current, duty cycle, mounting pattern, terminal type, cable connector layout must match |
Choosing and fitting
When selecting a replacement ignition transformer of this type, ensure the primary voltage (e.g., 230 V, 110 V, or 24 V), secondary voltage and current, duty cycle, mounting pattern, terminal type, and cable connector layout match the original. Measure the physical dimensions and mounting hole spacing to confirm compatibility. Check the number of high-voltage outputs and the type of ignition cable insulation (e.g., silicone) required for the application.
Signs of failure
Common failure modes include cracked or hardened ignition cables that leak spark to earth, mimicking a transformer failure. The equipment may fail to ignite or exhibit intermittent sparking. Check the cables and connectors for damage before condemning the transformer. Other issues can include internal short circuits or open windings, leading to no spark output.
All specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 14 kV |
| Poles / outlets | 2 |
| Length | 150 mm |
| Width | 87 mm |
| Height | 80 mm |
| Ignition cable insulation | silicone-insulated |
| Operating phase | ignition phase only |
| Dimensions | 150x87x80 mm |
| Number of outputs | 2 |
| High voltage outputs | 2 |
| Current consumption | 2.1–2.3 A |
| External package dimensions (LxWxH) | 190x130x105 |
| Energization | energised only during ignition phase |
| Net weight | 2.71 kg |
| Gross weight | 2.785 kg |
| Frequency | 50 Hz |
Part numbers
| SKU | TRG1230 |
|---|---|
| Additional article | 309.820.038 |