Cofi Ignition transformer TRG823PC
SKU TRG823PC
Brand Cofi
Photos
Key specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 8 kV |
| Length | 190 mm |
| Width | 130 mm |
| Height | 105 mm |
| Current | 0.9 A |
| Catalogue article numbers | 309.820.035 |
| Manufacturer code | TRG823PC |
| Ignition cable insulation | silicone-insulated |
| Net weight | 2.73 kg |
| Gross weight | 2.805 kg |
| Frequency | 50 Hz |
123.53 EUR
112.30EUR
in stock · 1
incl. 21% VAT · 92.81 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Cofi Ignition transformer TRG823PC is a high-voltage ignition transformer designed for automatic ignition systems in gas and liquid fuel burners. It operates with a supply voltage of 230 V at 50 Hz, drawing a current of 0.9 A. The transformer provides a secondary voltage of 8 kV to generate a stable spark for fuel ignition. It has a net weight of 2.73 kg and dimensions of 190 mm in length, 130 mm in width, and 105 mm in height. The ignition cable is silicone-insulated to withstand high voltage and heat.
Further details
| Advantages | stable high-voltage spark; reliable burner startup; original cofi transformer; suitable for gas and diesel burners; high reliability during long-term operation; compatibility with industrial ignition systems |
|---|---|
| Application | gas burners; diesel burners; dual-fuel burners; boiler equipment; industrial heat generators; automatic ignition systems |
| Cable condition | must be inspected for hardening or cracking |
| Operating phase | energised only during the ignition phase |
| Troubleshooting | inspect cables and connections before concluding transformer is defective |
Choosing and fitting
When selecting a replacement ignition transformer of this type, key parameters to match include the primary voltage (commonly 230 V, but also 110 V or 24 V versions exist), the secondary voltage and current, and the duty cycle (intermittent operation). The mounting configuration and terminal arrangement must correspond to the existing setup. The cable connector pattern must also match the electrode assembly. Always inspect the ignition cables and connections before ordering, as a hardened or cracked cable can cause spark leakage, which may appear as a transformer fault.
Signs of failure
Typical failures of ignition transformers include internal short circuits or open windings, leading to no spark or weak spark at the electrode. The burner may fail to ignite or experience intermittent ignition, causing the control to lock out. Check the ignition cable for cracks or hardening, as this can leak the spark to earth, mimicking a transformer fault. Also, verify the primary voltage and connections to ensure proper operation.
All specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 8 kV |
| Length | 190 mm |
| Width | 130 mm |
| Height | 105 mm |
| Current | 0.9 A |
| Catalogue article numbers | 309.820.035 |
| Manufacturer code | TRG823PC |
| Ignition cable insulation | silicone-insulated |
| Net weight | 2.73 kg |
| Gross weight | 2.805 kg |
| Frequency | 50 Hz |
Part numbers
| SKU | TRG823PC |
|---|---|
| Additional article | 309.820.035 |