Cofi Ignition transformer TRG823PC

SKU TRG823PC Brand Cofi

Photos

Key specifications

Supply voltage230 V
Secondary voltage8 kV
Length190 mm
Width130 mm
Height105 mm
Current0.9 A
Catalogue article numbers309.820.035
Manufacturer codeTRG823PC
Ignition cable insulationsilicone-insulated
Net weight2.73 kg
Gross weight2.805 kg
Frequency50 Hz
all specifications (12) ↓
123.53 EUR
112.30EUR
in stock · 1

incl. 21% VAT · 92.81 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Cofi Ignition transformer TRG823PC is a high-voltage ignition transformer designed for automatic ignition systems in gas and liquid fuel burners. It operates with a supply voltage of 230 V at 50 Hz, drawing a current of 0.9 A. The transformer provides a secondary voltage of 8 kV to generate a stable spark for fuel ignition. It has a net weight of 2.73 kg and dimensions of 190 mm in length, 130 mm in width, and 105 mm in height. The ignition cable is silicone-insulated to withstand high voltage and heat.

Further details

Advantagesstable high-voltage spark; reliable burner startup; original cofi transformer; suitable for gas and diesel burners; high reliability during long-term operation; compatibility with industrial ignition systems
Applicationgas burners; diesel burners; dual-fuel burners; boiler equipment; industrial heat generators; automatic ignition systems
Cable conditionmust be inspected for hardening or cracking
Operating phaseenergised only during the ignition phase
Troubleshootinginspect cables and connections before concluding transformer is defective

Choosing and fitting

When selecting a replacement ignition transformer of this type, key parameters to match include the primary voltage (commonly 230 V, but also 110 V or 24 V versions exist), the secondary voltage and current, and the duty cycle (intermittent operation). The mounting configuration and terminal arrangement must correspond to the existing setup. The cable connector pattern must also match the electrode assembly. Always inspect the ignition cables and connections before ordering, as a hardened or cracked cable can cause spark leakage, which may appear as a transformer fault.

Signs of failure

Typical failures of ignition transformers include internal short circuits or open windings, leading to no spark or weak spark at the electrode. The burner may fail to ignite or experience intermittent ignition, causing the control to lock out. Check the ignition cable for cracks or hardening, as this can leak the spark to earth, mimicking a transformer fault. Also, verify the primary voltage and connections to ensure proper operation.

All specifications

Supply voltage230 V
Secondary voltage8 kV
Length190 mm
Width130 mm
Height105 mm
Current0.9 A
Catalogue article numbers309.820.035
Manufacturer codeTRG823PC
Ignition cable insulationsilicone-insulated
Net weight2.73 kg
Gross weight2.805 kg
Frequency50 Hz