Cofi Ignition transformer TRK2-40HD
SKU TRK2-40HD
Brand Cofi
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 10 kV |
| Poles / outlets | 2 |
| Length | 170 mm |
| Width | 90 mm |
| Height | 55 mm |
| Construction type | electronic (high-frequency), with center grounding |
| Secondary grounding | center grounding |
| Dimensions | 170 x 90 x 55 mm |
| Housing type | compact |
| Ignition voltage | 10–10 kV |
| Weight | 330 g |
| Function | step-up transformer |
| Ignition current | 40 mA |
| Current frequency | 50–60 Hz |
| Number of outputs | 2 |
| Duration of ED(DU) operation | 33 % |
| High voltage outputs | 2 |
| Current | 0.3 A |
| Number of poles | 2 |
| Epoxy potting | epoxy potting |
| Technology | high-frequency electronic circuitry |
| Operating principle | step-up transformer |
| Installation type | easily installed in limited space |
| Ignition cable insulation | silicone-insulated |
| Cable insulation type | silicone |
| Input voltage range | 220-240V |
| Output type | two high-voltage outputs |
| Protection against moisture, vibration, overheating | high protection |
| Energy efficiency | energy efficient |
| Low noise | low noise level |
| Manufacturer code | TRK2-40HD |
| Mounting arrangement | depends on |
| Terminal type | depends on |
| Cable connector pattern | depends on |
| Working with | ignition electrode and burner control |
| Pre-purge phase | after pre-purge phase |
| Inspect cables | inspect ignition cables for damage |
| Secondary current | 40 mA |
| Duty cycle | depends on |
| Net weight | 0.33 kg |
| Gross weight | 0.365 kg |
| Power consumption | 65 W |
| Frequency | 50–60 Hz |
| Ambient temperature, max | 60 °C |
| Country of origin | Italy |
65.89 EUR
59.90EUR
in stock · 2
incl. 21% VAT · 49.50 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Cofi TRK2-40HD is an electronic high-frequency ignition transformer with center grounding, designed for low-power gas and liquid fuel burners. It operates on a 220-240 V supply at 50-60 Hz, drawing 0.3 A and consuming 65 W. The transformer provides two high-voltage outputs at 10 kV each, with an ignition current of 40 mA and a duty cycle of 33% within 3 minutes. Its compact dimensions (170 x 90 x 55 mm) and net weight of 0.33 kg allow easy installation in limited spaces. The unit features epoxy potting for protection against moisture, vibration, and overheating, and is compatible with burners from Riello, Ecoflam, FBR, Baltur, Lamborghini, Bentone, and Giersch.
Further details
| Application | gas and liquid fuel burners of low and medium power |
|---|---|
| Compatible burners | Riello, Ecoflam, FBR, Baltur, Lamborghini, Bentone, Giersch |
| Ignition cable condition | hardened or cracked cable can leak spark |
| Operating Phase | energised only during the ignition period |
| Replacement check | confirm primary voltage and connection pattern |
| Safety time | flame must be proved within safety time |
Choosing and fitting
When selecting a replacement ignition transformer of this type, verify that the primary voltage (e.g., 230 V) and frequency match the burner's supply, and that the secondary voltage and current are sufficient for the electrode gap. Confirm the duty cycle (e.g., 33% ED) aligns with the burner's ignition sequence, and check the mounting arrangement, terminal type, and cable connector pattern to ensure physical compatibility. The transformer is energized only during the ignition period, controlled by the burner's control box, so ensure the control signal and wiring match the new unit's specifications.
Signs of failure
Common failures in ignition transformers of this kind include internal short circuits or open windings, often caused by overheating or moisture ingress, leading to a weak or absent spark. Symptoms include the burner failing to ignite, repeated lockouts, or a visible spark leaking to ground due to damaged ignition cables. Before replacing the transformer, inspect the silicone-insulated ignition cables for cracks or hardening, as a faulty cable can mimic transformer failure. Also check the electrode gap and condition, as improper spacing can prevent spark generation.
Fits equipment
Riello Ecoflam FBR Baltur Lamborghini Bentone Giersch
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 10 kV |
| Poles / outlets | 2 |
| Length | 170 mm |
| Width | 90 mm |
| Height | 55 mm |
| Construction type | electronic (high-frequency), with center grounding |
| Secondary grounding | center grounding |
| Dimensions | 170 x 90 x 55 mm |
| Housing type | compact |
| Ignition voltage | 10–10 kV |
| Weight | 330 g |
| Function | step-up transformer |
| Ignition current | 40 mA |
| Current frequency | 50–60 Hz |
| Number of outputs | 2 |
| Duration of ED(DU) operation | 33 % |
| High voltage outputs | 2 |
| Current | 0.3 A |
| Number of poles | 2 |
| Epoxy potting | epoxy potting |
| Technology | high-frequency electronic circuitry |
| Operating principle | step-up transformer |
| Installation type | easily installed in limited space |
| Ignition cable insulation | silicone-insulated |
| Cable insulation type | silicone |
| Input voltage range | 220-240V |
| Output type | two high-voltage outputs |
| Protection against moisture, vibration, overheating | high protection |
| Energy efficiency | energy efficient |
| Low noise | low noise level |
| Manufacturer code | TRK2-40HD |
| Mounting arrangement | depends on |
| Terminal type | depends on |
| Cable connector pattern | depends on |
| Working with | ignition electrode and burner control |
| Pre-purge phase | after pre-purge phase |
| Inspect cables | inspect ignition cables for damage |
| Secondary current | 40 mA |
| Duty cycle | depends on |
| Net weight | 0.33 kg |
| Gross weight | 0.365 kg |
| Power consumption | 65 W |
| Frequency | 50–60 Hz |
| Ambient temperature, max | 60 °C |
| Country of origin | Italy |
Part numbers
| SKU | TRK2-40HD |
|---|---|
| Additional article | 309.820.085 |