{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Cofi Ignition transformer TRK2-40HD

SKU TRK2-40HD Brand Cofi

Photos

Key specifications

Supply voltage220–240 V
Secondary voltage10 kV
Poles / outlets2
Length170 mm
Width90 mm
Height55 mm
Construction typeelectronic (high-frequency), with center grounding
Secondary groundingcenter grounding
Dimensions170 x 90 x 55 mm
Housing typecompact
Ignition voltage10–10 kV
Weight330 g
Functionstep-up transformer
Ignition current40 mA
Current frequency50–60 Hz
Number of outputs2
Duration of ED(DU) operation33 %
High voltage outputs2
Current0.3 A
Number of poles2
Epoxy pottingepoxy potting
Technologyhigh-frequency electronic circuitry
Operating principlestep-up transformer
Installation typeeasily installed in limited space
Ignition cable insulationsilicone-insulated
Cable insulation typesilicone
Input voltage range220-240V
Output typetwo high-voltage outputs
Protection against moisture, vibration, overheatinghigh protection
Energy efficiencyenergy efficient
Low noiselow noise level
Manufacturer codeTRK2-40HD
Mounting arrangementdepends on
Terminal typedepends on
Cable connector patterndepends on
Working withignition electrode and burner control
Pre-purge phaseafter pre-purge phase
Inspect cablesinspect ignition cables for damage
Secondary current40 mA
Duty cycledepends on
Net weight0.33 kg
Gross weight0.365 kg
Power consumption65 W
Frequency50–60 Hz
Ambient temperature, max60 °C
Country of originItaly
all specifications (46) ↓
65.89 EUR
59.90EUR
in stock · 2

incl. 21% VAT · 49.50 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Cofi TRK2-40HD is an electronic high-frequency ignition transformer with center grounding, designed for low-power gas and liquid fuel burners. It operates on a 220-240 V supply at 50-60 Hz, drawing 0.3 A and consuming 65 W. The transformer provides two high-voltage outputs at 10 kV each, with an ignition current of 40 mA and a duty cycle of 33% within 3 minutes. Its compact dimensions (170 x 90 x 55 mm) and net weight of 0.33 kg allow easy installation in limited spaces. The unit features epoxy potting for protection against moisture, vibration, and overheating, and is compatible with burners from Riello, Ecoflam, FBR, Baltur, Lamborghini, Bentone, and Giersch.

Further details

Applicationgas and liquid fuel burners of low and medium power
Compatible burnersRiello, Ecoflam, FBR, Baltur, Lamborghini, Bentone, Giersch
Ignition cable conditionhardened or cracked cable can leak spark
Operating Phaseenergised only during the ignition period
Replacement checkconfirm primary voltage and connection pattern
Safety timeflame must be proved within safety time

Choosing and fitting

When selecting a replacement ignition transformer of this type, verify that the primary voltage (e.g., 230 V) and frequency match the burner's supply, and that the secondary voltage and current are sufficient for the electrode gap. Confirm the duty cycle (e.g., 33% ED) aligns with the burner's ignition sequence, and check the mounting arrangement, terminal type, and cable connector pattern to ensure physical compatibility. The transformer is energized only during the ignition period, controlled by the burner's control box, so ensure the control signal and wiring match the new unit's specifications.

Signs of failure

Common failures in ignition transformers of this kind include internal short circuits or open windings, often caused by overheating or moisture ingress, leading to a weak or absent spark. Symptoms include the burner failing to ignite, repeated lockouts, or a visible spark leaking to ground due to damaged ignition cables. Before replacing the transformer, inspect the silicone-insulated ignition cables for cracks or hardening, as a faulty cable can mimic transformer failure. Also check the electrode gap and condition, as improper spacing can prevent spark generation.

Fits equipment

Riello Ecoflam FBR Baltur Lamborghini Bentone Giersch

All specifications

Supply voltage220–240 V
Secondary voltage10 kV
Poles / outlets2
Length170 mm
Width90 mm
Height55 mm
Construction typeelectronic (high-frequency), with center grounding
Secondary groundingcenter grounding
Dimensions170 x 90 x 55 mm
Housing typecompact
Ignition voltage10–10 kV
Weight330 g
Functionstep-up transformer
Ignition current40 mA
Current frequency50–60 Hz
Number of outputs2
Duration of ED(DU) operation33 %
High voltage outputs2
Current0.3 A
Number of poles2
Epoxy pottingepoxy potting
Technologyhigh-frequency electronic circuitry
Operating principlestep-up transformer
Installation typeeasily installed in limited space
Ignition cable insulationsilicone-insulated
Cable insulation typesilicone
Input voltage range220-240V
Output typetwo high-voltage outputs
Protection against moisture, vibration, overheatinghigh protection
Energy efficiencyenergy efficient
Low noiselow noise level
Manufacturer codeTRK2-40HD
Mounting arrangementdepends on
Terminal typedepends on
Cable connector patterndepends on
Working withignition electrode and burner control
Pre-purge phaseafter pre-purge phase
Inspect cablesinspect ignition cables for damage
Secondary current40 mA
Duty cycledepends on
Net weight0.33 kg
Gross weight0.365 kg
Power consumption65 W
Frequency50–60 Hz
Ambient temperature, max60 °C
Country of originItaly

Part numbers

SKUTRK2-40HD
Additional article309.820.085