Cofi Ignition transformer TRL12-30C
SKU TRL12-30C
Brand Cofi
Photos
Key specifications
| Supply voltage | 12 V |
|---|---|
| Secondary voltage | 15 kV |
| Poles / outlets | 2 |
| Length | 90 mm |
| Width | 81 mm |
| Height | 40 mm |
| Manufacturer code | TRL12-30C |
| Ignition cable insulation | silicone-insulated |
| Net weight | 0.495 kg |
| Gross weight | 0.52 kg |
204.29 EUR
185.72EUR
in stock · 1
incl. 21% VAT · 153.49 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Cofi Ignition transformer TRL12-30C is a high-voltage ignition transformer designed to generate a spark in automatic ignition systems of gas, diesel, and dual-fuel burners. It operates from a 12 V supply voltage and provides a secondary voltage of 15 kV across 2 poles. The transformer measures 90 mm in length, 81 mm in width, and 40 mm in height, with a net weight of 0.495 kg and a gross weight of 0.52 kg. It features silicone-insulated ignition cable for high-voltage and heat resistance.
Further details
| Advantages | operation from low voltage 12v dc, stable spark formation, original cofi transformer, compact size, reliable operation in automatic ignition systems, resistance to loads, long service life |
|---|---|
| Application | gas burners, diesel burners, dual-fuel burners, boiler equipment, automatic ignition systems |
| Energization | energised by the burner control only during the ignition phase of the burner start sequence |
| Function | high-voltage ignition transformer designed to generate a spark in automatic ignition systems |
| Operating principle | steps up mains voltage to the high voltage required to produce a spark across the ignition electrode gap |
| Troubleshooting | inspect the cable and electrode assembly first |
Choosing and fitting
When selecting a replacement ignition transformer of this type, ensure the supply voltage matches the burner control (e.g., 12 V DC), and the secondary voltage and current are compatible with the ignition electrode gap. Physical dimensions, mounting arrangement, terminal type, and the connector pattern for the ignition cable must be compared with the original part. The ignition cable must be silicone-insulated to withstand high voltage and heat; inspect the cable and electrode assembly before ordering.
Signs of failure
Typical failures of ignition transformers include internal short circuits, open windings, or insulation breakdown, leading to weak or no spark at the electrodes. Equipment may fail to ignite, lockout after repeated attempts, or show intermittent ignition. Check for cracked or hardened ignition cable that can leak spark to earth, mimicking a faulty transformer, and verify the transformer's output with a high-voltage probe.
All specifications
| Supply voltage | 12 V |
|---|---|
| Secondary voltage | 15 kV |
| Poles / outlets | 2 |
| Length | 90 mm |
| Width | 81 mm |
| Height | 40 mm |
| Manufacturer code | TRL12-30C |
| Ignition cable insulation | silicone-insulated |
| Net weight | 0.495 kg |
| Gross weight | 0.52 kg |
Part numbers
| SKU | TRL12-30C |
|---|---|
| Additional article | 309.820.031 |