{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Cofi Ignition transformer TRL12-30C

SKU TRL12-30C Brand Cofi

Photos

Key specifications

Supply voltage12 V
Secondary voltage15 kV
Poles / outlets2
Length90 mm
Width81 mm
Height40 mm
Manufacturer codeTRL12-30C
Ignition cable insulationsilicone-insulated
Net weight0.495 kg
Gross weight0.52 kg
all specifications (10) ↓
204.29 EUR
185.72EUR
in stock · 1

incl. 21% VAT · 153.49 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Cofi Ignition transformer TRL12-30C is a high-voltage ignition transformer designed to generate a spark in automatic ignition systems of gas, diesel, and dual-fuel burners. It operates from a 12 V supply voltage and provides a secondary voltage of 15 kV across 2 poles. The transformer measures 90 mm in length, 81 mm in width, and 40 mm in height, with a net weight of 0.495 kg and a gross weight of 0.52 kg. It features silicone-insulated ignition cable for high-voltage and heat resistance.

Further details

Advantagesoperation from low voltage 12v dc, stable spark formation, original cofi transformer, compact size, reliable operation in automatic ignition systems, resistance to loads, long service life
Applicationgas burners, diesel burners, dual-fuel burners, boiler equipment, automatic ignition systems
Energizationenergised by the burner control only during the ignition phase of the burner start sequence
Functionhigh-voltage ignition transformer designed to generate a spark in automatic ignition systems
Operating principlesteps up mains voltage to the high voltage required to produce a spark across the ignition electrode gap
Troubleshootinginspect the cable and electrode assembly first

Choosing and fitting

When selecting a replacement ignition transformer of this type, ensure the supply voltage matches the burner control (e.g., 12 V DC), and the secondary voltage and current are compatible with the ignition electrode gap. Physical dimensions, mounting arrangement, terminal type, and the connector pattern for the ignition cable must be compared with the original part. The ignition cable must be silicone-insulated to withstand high voltage and heat; inspect the cable and electrode assembly before ordering.

Signs of failure

Typical failures of ignition transformers include internal short circuits, open windings, or insulation breakdown, leading to weak or no spark at the electrodes. Equipment may fail to ignite, lockout after repeated attempts, or show intermittent ignition. Check for cracked or hardened ignition cable that can leak spark to earth, mimicking a faulty transformer, and verify the transformer's output with a high-voltage probe.

All specifications

Supply voltage12 V
Secondary voltage15 kV
Poles / outlets2
Length90 mm
Width81 mm
Height40 mm
Manufacturer codeTRL12-30C
Ignition cable insulationsilicone-insulated
Net weight0.495 kg
Gross weight0.52 kg

Part numbers

SKUTRL12-30C
Additional article309.820.031