{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Cofi High-voltage ignition transformer TRL24-30C

SKU TRL24-30C Brand Cofi

Photos

Key specifications

Supply voltage24 V
Secondary voltage15 kV
Poles / outlets2
Length118 mm
Width84 mm
Height42 mm
Ignition cable insulationsilicone-insulated
Operating phaseignition phase only
Long service lifelong service life
Net weight0.506 kg
Gross weight0.541 kg
all specifications (11) ↓
204.29 EUR
185.72EUR
in stock · 2

incl. 21% VAT · 153.49 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Cofi TRL24-30C is a high-voltage ignition transformer designed for automatic ignition systems in gas and liquid fuel burners. It operates on a 24 V supply voltage and provides a secondary voltage of 15 kV across two poles. The transformer measures 118 mm in length, 84 mm in width, and 42 mm in height, with a net weight of 0.506 kg and a gross weight of 0.541 kg. It is intended for use during the ignition phase only and features silicone-insulated ignition cable for durability.

Choosing and fitting

When selecting a replacement ignition transformer of this type, ensure the primary voltage matches the burner supply (e.g., 24 V, 110 V, or 230 V). The secondary voltage and current must be sufficient to reliably ignite the air-fuel mixture. Verify the duty cycle to ensure it can operate for the required ignition period without overheating. Physical mounting dimensions, terminal types, and the connector pattern for the high-voltage cable must also match the existing setup. Always inspect the ignition cable and electrode condition before installation.

Signs of failure

Common failure modes for ignition transformers include internal short circuits, open windings, or insulation breakdown, leading to weak or no spark. Symptoms on the equipment include failure to ignite, intermittent ignition, or burner lockout. Check the transformer for visible damage, measure primary and secondary voltages, and inspect the ignition cable for cracks or hardening that could cause spark leakage to ground.

All specifications

Supply voltage24 V
Secondary voltage15 kV
Poles / outlets2
Length118 mm
Width84 mm
Height42 mm
Ignition cable insulationsilicone-insulated
Operating phaseignition phase only
Long service lifelong service life
Net weight0.506 kg
Gross weight0.541 kg

Part numbers

SKUTRL24-30C
Additional article309.820.030