Cofi Ignition transformer TRS1020

SKU TRS1020 Brand Cofi

Photos

Key specifications

Supply voltage230 V
Secondary voltage5 kV
Current1.1 A
Catalogue article numbers309.820.032
Manufacturer codeTRS1020
Ignition cable insulationsilicone-insulated
Frequency50 Hz
all specifications (7) ↓
91.93 EUR
83.57EUR
in stock · 2

incl. 21% VAT · 69.07 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Cofi Ignition transformer TRS1020 is a high-voltage ignition transformer designed to generate a spark in automatic ignition systems for gas, diesel, and dual-fuel burners. It operates with a supply voltage of 230 V at 50 Hz, drawing a current of 1.1 A. The secondary voltage is 5 kV, and the ignition cable insulation is silicone-insulated. This transformer is used in boiler plants and industrial burners requiring a stable high-voltage source for ignition electrodes.

Further details

Advantagesstable high voltage for reliable ignition; original cofi transformer; high reliability and durability; load resistance; suitable for automatic ignition systems; easy replacement and installation
Application scopegas burners; diesel burners; dual-fuel burners; boiler equipment; industrial ignition systems
Working withburner control, ignition electrode, flame-proving system

Choosing and fitting

Parts of this type are selected by matching the primary voltage (230 V is common, but 110 V and 24 V variants exist), secondary voltage and current, duty cycle, mounting and terminal arrangement, and cable connector pattern. Before ordering, measure the mounting dimensions and compare the terminal layout with the existing unit. Ensure the high-voltage cable connector matches the electrode assembly.

Signs of failure

Typical failures include internal short circuits or open windings, leading to no spark or weak spark. The burner may fail to ignite or lockout after repeated ignition attempts. Check the high-voltage cables for hardening or cracking, as a leak to earth can mimic a failed transformer. Also verify the primary voltage and connections before condemning the transformer.

All specifications

Supply voltage230 V
Secondary voltage5 kV
Current1.1 A
Catalogue article numbers309.820.032
Manufacturer codeTRS1020
Ignition cable insulationsilicone-insulated
Frequency50 Hz

Part numbers

SKUTRS1020
Additional article309.820.032