Supply voltage230 V
Ignition cable insulationsilicone-insulated
Housing typecompact
Catalogue article numbers309.820.071
Functionstep-up transformer
Design featurescompact design
Manufacturer codeTRS610PC/5
Compact designcompact
Compact sizecompact
Power supply230 V
Operating principlestep-up transformer
Country of originItaly
all specifications (12) ↓
126.47 EUR
114.97EUR
in stock · 2

incl. 21% VAT · 95.02 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Cofi Ignition transformer TRS610PC/5 is a step-up transformer that operates from a 230 V power supply. It is designed for use in low-power diesel and fuel oil burners, providing the high-voltage spark needed for ignition. The transformer features a compact housing and silicone-insulated ignition cable. It is manufactured in Italy and carries the article number 309.820.071.

Further details

Application scopelow-power diesel and fuel oil burners, heating boilers, heat generators, industrial equipment
Benefitsensures stable burner start-up and safe equipment operation

Choosing and fitting

When selecting a replacement ignition transformer of this kind, verify the primary voltage (e.g., 230 V), secondary voltage and current ratings, duty cycle, mounting dimensions, terminal arrangement, and cable connector pattern. The mounting style and connector layout vary between manufacturers, so compare these with the original part before ordering. Ensure the high-voltage cable is silicone-insulated and check the electrode gap.

Signs of failure

Typical failures of this kind include a weak or absent spark due to a hardened or cracked ignition cable leaking current to earth, or a faulty transformer. The burner may fail to ignite or lock out after the safety time. Check the primary voltage supply from the control, the continuity of the secondary circuit including cables and electrodes, and the condition of the cable insulation.

All specifications

Supply voltage230 V
Ignition cable insulationsilicone-insulated
Housing typecompact
Catalogue article numbers309.820.071
Functionstep-up transformer
Design featurescompact design
Manufacturer codeTRS610PC/5
Compact designcompact
Compact sizecompact
Power supply230 V
Operating principlestep-up transformer
Country of originItaly

Part numbers

SKUTRS610PC/5
Additional article309.820.071