Cofi Ignition transformer TRS818C/29
SKU TRS818C/29
Brand Cofi
Photos
Key specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 8 kV |
| Length | 110 mm |
| Width | 90 mm |
| Height | 70 mm |
| Body material | robust housing |
| Construction type | induction |
| Operating principle | step-up transformer |
| Ignition cable insulation | silicone-insulated |
| Output voltage frequency | 2x4 kV |
| Output current | 0.9 A |
| Working with | ignition electrode(s) and control box |
| Frequency | 50 Hz |
| Country of origin | Italy |
115.67 EUR
105.15EUR
in stock · 1
incl. 21% VAT · 86.90 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Cofi Ignition transformer TRS818C/29 is a step-up transformer designed for use in burners and boilers. It operates on a supply voltage of 230 V at 50 Hz and provides a secondary voltage of 8 kV, split into two outputs of 4 kV each, with an output current of 0.9 A. This induction-type transformer is housed in a robust body and features silicone-insulated ignition cables. It is intended to work with ignition electrodes and a control box to generate sparks for fuel ignition.
Further details
| Advantages | stable spark generation, safe burner start-up, uninterrupted operation |
|---|---|
| Application scope | high-power gas, diesel, and heavy fuel oil burners |
| Cable condition check | inspect cable and electrode before concluding transformer failure |
| No compatibility details | no specific electrical ratings or compatibility with particular burner models are stated |
| Operating Phase | energised only during the ignition phase |
| Replacement considerations | confirm required specifications from burner manufacturer documentation |
| Troubleshooting | check ignition cable and electrode condition |
Choosing and fitting
When selecting a replacement ignition transformer of this kind, verify that the primary voltage, secondary voltage, and output current match the burner's requirements. Check the mounting dimensions and terminal configuration to ensure compatibility with the existing setup. The ignition cable must be silicone-insulated to withstand high voltage and temperature. Always confirm specifications from the burner manufacturer's documentation or the existing part marking before ordering.
Signs of failure
Common failure modes for ignition transformers include cracked or hardened ignition cables that leak spark to ground, leading to weak or no spark. The equipment may fail to ignite or exhibit intermittent ignition. Check the condition of the cable and electrode before concluding the transformer is faulty. Overheating or mechanical damage can also cause internal short circuits, resulting in a complete loss of spark.
All specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 8 kV |
| Length | 110 mm |
| Width | 90 mm |
| Height | 70 mm |
| Body material | robust housing |
| Construction type | induction |
| Operating principle | step-up transformer |
| Ignition cable insulation | silicone-insulated |
| Output voltage frequency | 2x4 kV |
| Output current | 0.9 A |
| Working with | ignition electrode(s) and control box |
| Frequency | 50 Hz |
| Country of origin | Italy |
Part numbers
| SKU | TRS818C/29 |
|---|---|
| Additional article | 309.820.065 |