Danfoss High-voltage ignition transformer EBI4 CM S 052F4047

SKU 052F4047 Model EBI4 CM S Brand Danfoss

Photos

Key specifications

Supply voltage220–240 V
Ignition current30 mA
Current0.25 A
Catalogue article numbers327.820.001
Manufacturer code052F4047
Ignition cable insulationsilicone-insulated
Cable condition checkcheck before replacing transformer
Secondary current30 mA
Frequency50–60 Hz
all specifications (9) ↓
95.83 EUR
87.12EUR
in stock · 5

incl. 21% VAT · 72.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

Danfoss EBI4 CM S high-voltage ignition transformer, SKU 052F4047, operates at 220–240 V supply voltage and 50–60 Hz frequency. It provides a secondary current of 30 mA and draws a primary current of 0.25 A. This transformer is used in burners to step up mains voltage to produce a spark for igniting the fuel-air mixture during the ignition phase. The ignition cables are silicone-insulated to withstand high voltage and heat.

Further details

Applicationfor burners and industrial heating systems
Energizationenergised only during the ignition phase
Replacement verificationverify primary voltage and secondary output

Choosing and fitting

When selecting a replacement ignition transformer of this type, verify the primary voltage (typically 230 V, but 110 V and 24 V versions exist) and secondary output (voltage and current) against the burner control requirements and electrode gap specifications. Parts are chosen by secondary voltage and current, primary voltage, duty cycle, mounting arrangement, terminal type, and cable connector pattern. Before ordering, compare these specifications with the existing unit and ensure the mounting form matches.

Signs of failure

Common failure modes include internal short circuits or open windings, leading to no spark or weak spark. A hardened or cracked ignition cable can leak the spark to earth, mimicking a faulty transformer. Check the cable condition before replacing the transformer itself. If the burner fails to ignite or has intermittent ignition, inspect the transformer and cables for damage.

All specifications

Supply voltage220–240 V
Ignition current30 mA
Current0.25 A
Catalogue article numbers327.820.001
Manufacturer code052F4047
Ignition cable insulationsilicone-insulated
Cable condition checkcheck before replacing transformer
Secondary current30 mA
Frequency50–60 Hz

Part numbers

SKU052F4047
Additional article327.820.001
ModelEBI4 CM S