{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Fida Ignition transformer TF084D

SKU TF084D Brand Fida

Photos

Key specifications

Supply voltage230 V
Secondary voltage8 kV
Ignition cable insulationsilicone
Operating phaseignition phase only
Maximum length of ignition cable with integrated electronic ignition400 m
Advantagescompact, reliable, protected
Benefitsstable operation, efficient ignition
Maintenance requirementcheck cable condition
Troubleshootingcheck cable and electrode
Replacement considerationsconfirm ratings and mounting
Replacement verificationcheck electrode and cable
Energizationmomentary during ignition
Device typeignition transformer
Ignition cable conditionmust be verified
all specifications (14) ↓
118.00 EUR
107.27EUR
in stock · 2

incl. 21% VAT · 88.65 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Fida Ignition transformer TF084D is a component for burner ignition systems, designed to step up the mains voltage to generate a spark at the ignition electrode. It operates with a supply voltage of 230 V and produces a secondary voltage of 8 kV. The transformer is energized only during the ignition phase, under command from the burner control, and is protected against dust and moisture. It features a silicone-insulated ignition cable with a maximum length of 400 mm. This model is compatible with the Fida Compact 8/20PM burner.

Choosing and fitting

When selecting a replacement ignition transformer of this type, confirm that the primary and secondary voltage ratings match the original part, and that the mounting and connector arrangement are compatible. The transformer is typically mounted using plugs for electrical connection, and the ignition cable must be silicone-insulated to withstand high voltage and heat. Verify the physical dimensions and mounting method to ensure a proper fit.

Signs of failure

Common failure modes for ignition transformers of this kind include cracked or hardened ignition cables, which can leak the spark to earth and imitate a faulty transformer. If the transformer fails, the burner may not ignite or may shut down during operation. Check the condition of the ignition cable and electrode before concluding that the transformer itself is defective.

Fits equipment

Fida Compact 8/20PM

All specifications

Supply voltage230 V
Secondary voltage8 kV
Ignition cable insulationsilicone
Operating phaseignition phase only
Maximum length of ignition cable with integrated electronic ignition400 m
Advantagescompact, reliable, protected
Benefitsstable operation, efficient ignition
Maintenance requirementcheck cable condition
Troubleshootingcheck cable and electrode
Replacement considerationsconfirm ratings and mounting
Replacement verificationcheck electrode and cable
Energizationmomentary during ignition
Device typeignition transformer
Ignition cable conditionmust be verified

Part numbers

SKUTF084D
Additional article462.820.032