Fida Ignition transformer TZRDA
SKU TZRDA
Brand Fida
Photos
Key specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | determines the spark gap range |
| Poles / outlets | 1 |
| Length | 90 mm |
| Width | 53 mm |
| Height | 69 mm |
| Ingress protection | IP44 |
| Ignition cable connector | plug ø4 mm |
| Primary current | 0.32–0.32 A |
| Transformer type | compact, single-spark |
| Catalogue article numbers | TZRDA, 462.820.033 |
| Operation mode | continuous operation (ed 100%) |
| Housing type | sealed and compact housing |
| Application scope | gas and oil burners |
| Secondary current | 10 mA |
| Duty cycle | 100% |
| Frequency | 50 Hz |
112.61 EUR
102.37EUR
in stock · 2
incl. 21% VAT · 84.60 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Fida Ignition transformer TZRDA is a compact, single-spark transformer designed for gas and oil burners. It operates with a supply voltage of 230 V at 50 Hz and a primary current of 0.32 A. The secondary voltage determines the spark gap range, with a secondary current of 10 mA. It features a duty cycle of 100%, allowing continuous operation, and has an ingress protection rating of IP44. The transformer has one pole, measures 90 mm in length, 53 mm in width, and 69 mm in height, and includes an ignition cable connector with a plug of ø4 mm. Its article numbers are TZRDA and 462.820.033.
Further details
| Operating phase | operates only during the ignition period |
|---|---|
| Replacement considerations | inspect high-tension cables, verify mounting bracket and connector pattern, primary voltage |
Choosing and fitting
When selecting an ignition transformer of this type, ensure the primary voltage and frequency match the burner control output. The secondary voltage and current must be compatible with the electrode gap and spark energy requirements. Verify the physical dimensions, mounting points, and connector pattern (e.g., plug ø4 mm) align with the original part. Also, check the duty cycle rating to ensure it suits the burner's operational cycle.
Signs of failure
Common failures include no spark, intermittent operation, or weak ignition. This can be caused by worn or damaged internal components, cracked or hardened high-tension cables that leak spark to earth, or incorrect primary voltage. Inspect the high-tension cables for damage and verify the transformer's primary voltage and connector integrity.
All specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | determines the spark gap range |
| Poles / outlets | 1 |
| Length | 90 mm |
| Width | 53 mm |
| Height | 69 mm |
| Ingress protection | IP44 |
| Ignition cable connector | plug ø4 mm |
| Primary current | 0.32–0.32 A |
| Transformer type | compact, single-spark |
| Catalogue article numbers | TZRDA, 462.820.033 |
| Operation mode | continuous operation (ed 100%) |
| Housing type | sealed and compact housing |
| Application scope | gas and oil burners |
| Secondary current | 10 mA |
| Duty cycle | 100% |
| Frequency | 50 Hz |
Part numbers
| SKU | TZRDA |
|---|---|
| Additional article | 462.820.033 |