Kromschroder Ignition transformer TZI 8-12/100QT 84391131
SKU 84391131
Model TZI 8-12/100QT
Brand Kromschroder
Photos
no photo yet
Key specifications
| Supply voltage | 120 V |
|---|---|
| Secondary voltage | 8 kV |
| Poles / outlets | 1 |
| Standards | CE, UL |
| Protection class (IP) | IP00 |
| Installation type | control cabinet |
| Operating mode | continuous |
| Operating principle | step-up transformer |
| Ignition cable insulation | silicone-insulated |
| Replacement considerations | note high-voltage cable insulation |
| Secondary current | 9 mA |
| Duty cycle | 100% |
| Frequency | 50 Hz |
320.39 EUR
291.26EUR
in stock · 2
incl. 21% VAT · 240.71 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Kromschroder TZI 8-12/100QT is an ignition transformer used to generate a high-voltage spark for igniting gas or liquid fuel burners. It operates from a 120 V AC supply at 50 Hz, producing a secondary voltage of 8 kV with a secondary current of 9 mA. The transformer has a 100% duty cycle, allowing continuous operation, and is designed for installation in a control cabinet with IP00 protection. It features a single-pole output and is certified to CE and UL standards.
Further details
| Advantages | stable powerful spark, high reliability, long service life, easy installation |
|---|---|
| Application | industrial burners, boiler plants, drying chambers, thermal furnaces, heating lines |
| Energization | energised only during the ignition phase |
| Troubleshooting | verify cable condition and electrode gap |
Choosing and fitting
When selecting a replacement ignition transformer of this type, verify that the supply voltage, secondary voltage, and secondary current match the original specifications. The duty cycle must be suitable for the intended operating mode, and the mounting style should fit the existing control cabinet. Ensure the high-voltage cable is silicone-insulated to withstand the voltage and heat, and check the electrode gap before installation.
Signs of failure
Common failures of ignition transformers include internal short circuits or open windings, often caused by overheating or moisture ingress. Symptoms may include no spark at the electrode, weak spark, or intermittent ignition. Check the high-voltage cable for cracks or hardening, as this can cause current leakage to ground, and verify the electrode gap is correct before replacing the transformer.
All specifications
| Supply voltage | 120 V |
|---|---|
| Secondary voltage | 8 kV |
| Poles / outlets | 1 |
| Standards | CE, UL |
| Protection class (IP) | IP00 |
| Installation type | control cabinet |
| Operating mode | continuous |
| Operating principle | step-up transformer |
| Ignition cable insulation | silicone-insulated |
| Replacement considerations | note high-voltage cable insulation |
| Secondary current | 9 mA |
| Duty cycle | 100% |
| Frequency | 50 Hz |
Part numbers
| SKU | 84391131 |
|---|---|
| Additional article | 624.820.036 |
| Model | TZI 8-12/100QT |