Honeywell UV detector minipeeper C7035A1064/U
SKU C7035A1064/U
Brand Honeywell
Photos
Key specifications
| Detection principle | UV detector |
|---|---|
| Connection thread | 1/2-14 NPSM |
| Fuel | gas, oil or combined fuels |
| Application | flame monitoring systems |
| Detection principle | detect ultraviolet radiation |
| Wire length options | 6 ft [1.83 m] or 12 ft [3.66 m] |
| Catalogue article numbers | 534.211.034 |
| Compatible amplifiers | R7249A, R7290A, R7749B, R7849A, B |
| UV reading tube replaceable | Yes |
756.27 EUR
687.52EUR
in stock · 1
incl. 21% VAT · 568.20 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell UV detector minipeeper C7035A1064/U is an industrial flame sensor designed to detect ultraviolet radiation emitted by flames in burners running on gas, oil, or combined fuels. It is used in flame monitoring systems and is compatible with Honeywell amplifiers R7249A, R7290A, R7749B, R7849A, and R7849B. The detector features a 1/2-14 NPSM connection thread and is available with wire lengths of 6 ft [1.83 m] or 12 ft [3.66 m]. The UV reading tube is replaceable on-site. This model has an article number of 534.211.034.
Further details
| Housing standard | UL for moisture, NEMA type 4 and 4X |
|---|---|
| Installation requirements | direct visibility of flame, exclusion of other UV sources, proximity to flame, consider physical conditions and temperature restrictions |
| Parallel Connection | two flame detectors can be connected in parallel |
Choosing and fitting
Parts of this type are selected by ensuring compatibility with the amplifier model and checking the connection thread size, which must match the mounting. The detector is installed with a built-in cuff having an internal thread of 1-11-1/2 NPSM for a one-inch inspection tube. The wire length must be sufficient for the installation distance. The detector must be positioned with direct line of sight to the flame, away from other UV sources, and within allowable temperature and pressure limits.
Signs of failure
When items of this kind fail, the flame monitoring system may fail to detect the flame, causing the burner to shut down or fail to start. Common issues include a faulty UV tube, which can be replaced, or damage to the wires or housing. Check for proper electrical connections and ensure the detector is not exposed to excessive heat or pressure beyond its rated limits.
Fits equipment
Honeywell R7249AHoneywell R7290AHoneywell R7749BHoneywell R7849AHoneywell R7849B
All specifications
| Detection principle | UV detector |
|---|---|
| Connection thread | 1/2-14 NPSM |
| Fuel | gas, oil or combined fuels |
| Application | flame monitoring systems |
| Detection principle | detect ultraviolet radiation |
| Wire length options | 6 ft [1.83 m] or 12 ft [3.66 m] |
| Catalogue article numbers | 534.211.034 |
| Compatible amplifiers | R7249A, R7290A, R7749B, R7849A, B |
| UV reading tube replaceable | Yes |
Part numbers
| SKU | C7035A1064/U |
|---|---|
| Additional article | 534.211.034 |
| OEM equivalent | R7249A |
| OEM equivalent | R7290A |
| OEM equivalent | R7749B |
| OEM equivalent | R7849A |