{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Cofi Silicone insulator (boot) 04PL041442

SKU 04PL041442 Brand Cofi

Photos

Key specifications

Electrode length41 mm
Electrode diameter4.7–7 mm
Body materialhigh-temperature silicone
Country of originItaly
insulation_materialhigh-temperature silicone
Manufacturer part number04pl041442
Internal part number309.280.002
Compatible withcofi boots 11pc112013 or 11pc112010
High temperature resistanceup to +200°C and above
Wire diameter4.7–5.2 mm
Originalityoriginal
all specifications (11) ↓
10.78 EUR
9.80EUR
in stock · 2

incl. 21% VAT · 8.10 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This is a straight silicone insulator (boot) for ignition and ionization electrodes, manufactured by Cofi in Italy. It has a length of 41 mm and accommodates wire diameters of 4.7–5.2 mm, with an electrode diameter range of 4.7–7 mm. The body is made of high-temperature silicone, resistant to temperatures up to +200°C and above. It is compatible with Cofi boots 11PC112013 and 11PC112010, and serves as an OEM equivalent for those parts. The insulator provides electrical insulation and protection for the high-voltage wire connection to the electrode.

Further details

Aging resistanceresistant to oils, chemicals and aging
Application examplesindustrial and domestic gas burners (cib unigas, cofi, riello, ecoflam and similar) boiler rooms, drying chambers, bakery and process equipment regular maintenance and emergency repair
Breakdown protectiondesigned for reliable electrical insulation and protection of the high-voltage cable from breakdown, overheating, moisture and aggressive furnace environment
Chemical resistanceresistant to oils, chemicals and aging
Damage consequencea damaged insulator can cause spark leakage or loss of flame signal, leading to ignition failure or safety lockout
Electrical insulationdesigned for reliable electrical insulation and protection of the high-voltage cable from breakdown, overheating, moisture and aggressive furnace environment
Electrode rod insulationelectrically insulate the electrode rod from the burner head or mounting flange while providing mechanical support and maintaining the correct gap relative to the burner earth
Exposure conditionsexposed to high temperatures and combustion residues
Function descriptionprevents current leakage, short circuits and premature failure of the ignition transformer and electrodes
Furnace environment resistancedesigned for reliable electrical insulation and protection of the high-voltage cable from breakdown, overheating, moisture and aggressive furnace environment
Gap maintenancemaintaining the correct gap relative to the burner earth
Installation methodquickly slides onto the wire, provides sealing and protection of the connection with the ignition electrode
Length extendedextended version for more reliable insulation of the connection area
Mechanical supportproviding mechanical support and maintaining the correct gap relative to the burner earth
Moisture protectiondesigned for reliable electrical insulation and protection of the high-voltage cable from breakdown, overheating, moisture and aggressive furnace environment
Oil resistanceresistant to oils, chemicals and aging
Overheating protectiondesigned for reliable electrical insulation and protection of the high-voltage cable from breakdown, overheating, moisture and aggressive furnace environment
Protectionreliable protection for the high-voltage wire
Replacement checkcheck for cracks, glazing, or carbon tracking
Sealingprovides sealing and protection of the connection with the ignition electrode
Selection criteriaselection of such insulators is based on the inner diameter that matches the electrode rod, the outer diameter that fits the burner mounting bore, and the overall length and shape required by the burner series

Choosing and fitting

When selecting an insulator of this type, verify the inner diameter matches the electrode rod or wire diameter, and the outer diameter fits the burner mounting bore. Measure the overall length and shape to ensure it matches the original part. Check for compatibility with the specific electrode assembly and burner model. Installation involves sliding the insulator onto the wire and ensuring a secure seal over the connection.

Signs of failure

Insulators of this kind can fail due to cracking, glazing, or carbon tracking from high temperatures and combustion residues. A damaged insulator may cause spark leakage or loss of flame signal, leading to ignition failure or safety lockout. Inspect the insulator for visible damage and replace if any defects are found.

Fits equipment

Cofi 11pc112013Cofi 11pc112010

All specifications

Electrode length41 mm
Electrode diameter4.7–7 mm
Body materialhigh-temperature silicone
Country of originItaly
insulation_materialhigh-temperature silicone
Manufacturer part number04pl041442
Internal part number309.280.002
Compatible withcofi boots 11pc112013 or 11pc112010
High temperature resistanceup to +200°C and above
Wire diameter4.7–5.2 mm
Originalityoriginal

Part numbers

SKU04PL041442
Additional article309.280.002
OEM equivalent11PC112013
OEM equivalent11PC112010