Delavan Oil nozzles 00055-60W4
SKU 00055-60W4
Brand Delavan
Photos
Key specifications
| Flow rate | 0.55 GPH |
|---|---|
| Spray angle | 60 ° |
| Spray pattern | W |
| Capacity | 0.55 gallons/hour |
| Catalogue article numbers | 345.892.251 |
| Short name | Delavan 0.55GPH, 60W nozzle |
| Name (English) | Delavan 0.55GPH, 60W nozzle |
| SKU (English) | 00055-60W4, 345.892.251 |
| Function - fuel economy | contribute to fuel economy |
| Nozzle type | W |
| Capacity in kg per hour | 0.55 kg/h |
12.12 EUR
11.02EUR
in stock · 144
incl. 21% VAT · 9.11 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Delavan 00055-60W4 is an oil nozzle designed for use in burners, boilers, and heating systems. It has a capacity of 0.55 gallons per hour (GPH) and a spray angle of 60 degrees. The nozzle type is W, which indicates a specific spray pattern. This component regulates fuel flow and atomizes fuel for efficient combustion. It contributes to fuel economy by optimizing the fuel-air mixture.
Further details
| Application | heating systems, boilers, gas stoves and other devices |
|---|---|
| Combustion efficiency | efficient, stable and safe fuel combustion |
| Flame formation function | determine shape and structure of flame |
| Fuel dosage function | regulate amount of fuel entering burner |
| Fuel spraying function | convert fuel into fine droplet for good mixing with air |
| Function - flame formation | determine shape and structure of flame |
| Function - fuel dose adjustment | regulate amount of fuel entering burner |
Choosing and fitting
When selecting a replacement oil nozzle, ensure the capacity (GPH), spray angle, and spray pattern match the original specifications. The nozzle must be compatible with the burner's fuel pump pressure and the combustion chamber design. Installation involves removing the old nozzle and installing the new one with proper torque, ensuring no debris enters the fuel line.
Signs of failure
Common failure modes include clogging due to dirt or carbon deposits, which can cause uneven flame, soot formation, or reduced heating efficiency. A worn or damaged nozzle may lead to incomplete combustion, resulting in increased fuel consumption or visible smoke. Regular inspection and cleaning or replacement are recommended to maintain optimal burner performance.
All specifications
| Flow rate | 0.55 GPH |
|---|---|
| Spray angle | 60 ° |
| Spray pattern | W |
| Capacity | 0.55 gallons/hour |
| Catalogue article numbers | 345.892.251 |
| Short name | Delavan 0.55GPH, 60W nozzle |
| Name (English) | Delavan 0.55GPH, 60W nozzle |
| SKU (English) | 00055-60W4, 345.892.251 |
| Function - fuel economy | contribute to fuel economy |
| Nozzle type | W |
| Capacity in kg per hour | 0.55 kg/h |
Part numbers
| SKU | 00055-60W4 |
|---|---|
| Additional article | 345.892.251 |