{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Danfoss Oil pump BFP41 R3 071N7137

SKU 071N7137 Model BFP41 R3 Brand Danfoss

Photos

Key specifications

Protection class (IP)IP40
Setting range7000–20000 mbar
Max. pressure in suction/return line2 bar
Shaft rotation speed2400-3450 min
Max. starting torque0.1 nm
Ambient/transport temperature-20–70 °C
Fuel temperature0–70 °C
Max. inlet pressure2000 mbar
Flow rate11.0952 GPH
Torque, Nm0.1 Nm
Fuellight fuels and kerosene
Fuel viscosity1.8 cst
Filter area / cross-section11/200 cm2/microns
Fuel consumption42 l/h
Shaft materialEN225
Viscosity range (suction line)1.8-12.0 cst(mm2/s)
Pressure levels1
Application - Oil burnersdomestic burners
System typesingle and two-pipe systems
Built-in filtercassette filter
Shaft standardEN225
all specifications (21) ↓
price on request
on order

shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Danfoss BFP41 R3 oil pump (SKU 071N7137) is a gear pump designed for domestic burners with a fuel consumption up to 42 l/h. It operates with light fuels and kerosene, supporting both single and two-pipe systems. The pump features a single pressure level, a built-in pressure regulator, solenoid valve, and cassette filter. Its technical specifications include a pressure range of 7000–20000 mbar, a maximum inlet pressure of 2000 mbar, and a flow rate of 11.0952 GPH. The pump is suitable for fuel temperatures from 0 to 70 °C and ambient/transport temperatures from -20 to 70 °C, with a protection class of IP40.

Further details

Coil protection degreeIP40
Factory settings10 ±1 bar
ShaftEN225

Choosing and fitting

When selecting a replacement oil pump of this type, ensure that the shaft standard (EN225) and rotation speed range (2400-3450 min) match the burner's drive. Verify the pressure range and maximum inlet pressure are compatible with the system's requirements. The pump must support the fuel type and viscosity (1.8-12.0 cst) used in the installation. Check the mounting dimensions and shaft configuration to confirm physical fit.

Signs of failure

Common failures in oil pumps of this kind include loss of pressure due to worn gears or a clogged filter, leading to burner ignition issues or unstable flame. A faulty solenoid valve may cause fuel leakage or improper shutdown. Symptoms may include the burner failing to start, pulsating operation, or soot formation. Inspect the filter and pressure regulator for debris or damage, and verify the shaft coupling for wear.

All specifications

Protection class (IP)IP40
Setting range7000–20000 mbar
Max. pressure in suction/return line2 bar
Shaft rotation speed2400-3450 min
Max. starting torque0.1 nm
Ambient/transport temperature-20–70 °C
Fuel temperature0–70 °C
Max. inlet pressure2000 mbar
Flow rate11.0952 GPH
Torque, Nm0.1 Nm
Fuellight fuels and kerosene
Fuel viscosity1.8 cst
Filter area / cross-section11/200 cm2/microns
Fuel consumption42 l/h
Shaft materialEN225
Viscosity range (suction line)1.8-12.0 cst(mm2/s)
Pressure levels1
Application - Oil burnersdomestic burners
System typesingle and two-pipe systems
Built-in filtercassette filter
Shaft standardEN225

Part numbers

SKU071N7137
Additional article327.520.135
ModelBFP41 R3