Danfoss Oil pump RSA125 070-3410

SKU 070-3410 Model RSA125 Brand Danfoss

Photos

Key specifications

Viscosity range (suction line)1.3-75.0 cSt
Filter area / cross-section75/150 cm2/microns
Setting range5500–21000 mbar
Max. pressure in suction/return line4 bar
Shaft rotation speed1400-3450 min
Max. starting torque0.22 nm
Ambient temperature-20–70 °C
Storage temperature-25–70 °C
Fuel temperature-10–70 °C
Fueldiesel fuel and kerosene
Factory set pressure7 bar
Shaft materialen225
Fuel consumption255 l/h
System type1 and 2 pipe operation modes
Pump typegear pump
Built-in filterannular filter
Pressure levels1
Transport pumpyes
all specifications (18) ↓
870.47 EUR
791.34EUR
in stock · 2

incl. 21% VAT · 654.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Danfoss RSA125 oil pump (SKU 070-3410) is a gear pump designed for small and medium-sized household burners with a fuel consumption of up to 255 l/h. It operates with diesel fuel and kerosene, supporting both 1 and 2 pipe operation modes. The pump features a built-in pressure regulator with a shut-off function and an annular filter. It can be used as a transport or feed pump, with a factory-set pressure of 7 bar and a pressure range of 5500–21000 mbar. The pump has a viscosity range of 1.3–75.0 cSt in the suction line, a filter area cross-section of 75/150 cm2/microns, and a shaft rotation speed of 1400–3450 min.

Further details

Control Featuresbuilt-in regulator with a shut-off function
Factory settings7+-1 bar
ShaftEN225

Choosing and fitting

When selecting a replacement oil pump of this type, ensure the shaft rotation speed, pressure range, and fuel type match the burner's specifications. Verify the pump's mounting dimensions and shaft type (e.g., EN225) against the original. Check the system's operation mode (1 or 2 pipe) and confirm the pump supports it. Also, compare the factory-set pressure and adjust if necessary to match the burner's requirements.

Signs of failure

Common failures of this pump type include loss of pressure due to worn gears or a clogged filter, leading to burner ignition issues or unstable flame. Leaks may occur at the shaft seal, causing fuel drips. If the pump fails to start or makes excessive noise, check for contamination in the fuel or air in the suction line. Inspect the built-in filter and replace it if blocked.

All specifications

Viscosity range (suction line)1.3-75.0 cSt
Filter area / cross-section75/150 cm2/microns
Setting range5500–21000 mbar
Max. pressure in suction/return line4 bar
Shaft rotation speed1400-3450 min
Max. starting torque0.22 nm
Ambient temperature-20–70 °C
Storage temperature-25–70 °C
Fuel temperature-10–70 °C
Fueldiesel fuel and kerosene
Factory set pressure7 bar
Shaft materialen225
Fuel consumption255 l/h
System type1 and 2 pipe operation modes
Pump typegear pump
Built-in filterannular filter
Pressure levels1
Transport pumpyes

Part numbers

SKU070-3410
Additional article327.520.053
ModelRSA125