Danfoss Oil burner pump RSA60 070L3350
SKU 070L3350
Model RSA60
Brand Danfoss
Photos
no photo yet
Key specifications
| Filter area / cross-section | 75/150 cm2/microns |
|---|---|
| Setting range | 5500–21000 mbar |
| Max. starting torque | 0.24 nm |
| Ambient temperature | -20–70 °C |
| Storage temperature | -25–70 °C |
| Fuel temperature | -10–70 °C |
| Fuel | light fuel and kerosene |
| Max. pressure in suction/return line | 4 bar |
| Pump type | gear pump |
| Shaft material | en225 |
| Shaft rotation speed | 1400-3450 min |
| Viscosity range (suction line) | 1.3-75cst(mm2/s) |
| Built-in filter | annular filter |
| System type | single-tube and double-tube |
| Factory set pressure | 7 bar |
| Integrated filter | annular filter |
| Pressure levels | 1 |
| Transport pump | yes |
| Application | small and medium-sized household burners |
| Fuel consumption | 255 l/h |
| Shaft standard | EN225 |
| Filter type | annular filter |
525.75 EUR
477.95EUR
in stock · 26
incl. 21% VAT · 395.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Danfoss RSA60 070L3350 is a gear-type oil pump designed for small and medium-sized household burners with a maximum fuel consumption of 255 liters per hour. It operates on light fuel and kerosene, supporting both single-tube and double-tube systems with one pressure level. The pump features a built-in annular filter, a pressure regulator with a locking device, and a factory-set pressure of 7 bar. It can function as a transport or feed pump, with a pressure range of 5500–21000 mbar and a shaft rotation speed of 1400–3450 min. The pump is suitable for ambient temperatures from -20 to 70 °C and fuel temperatures from -10 to 70 °C.
Further details
| Control Features | built-in regulator with locking device function and special spring |
|---|---|
| Factory settings | 7+-1 bar |
| Pressure regulating valve | built-in regulator with locking device function |
| Shaft | EN225 |
Choosing and fitting
When selecting a replacement oil pump of this type, ensure the shaft standard (e.g., EN225), rotation speed range, and pressure range match the burner's requirements. Verify the system type (single-tube or double-tube) and the fuel type compatibility. The pump's mounting dimensions and shaft coupling must align with the existing burner assembly. Compare the factory-set pressure and the maximum pressure in the suction/return line to the system's specifications before installation.
Signs of failure
Common failures in oil pumps of this kind include loss of pressure due to worn gears or a clogged filter, leading to burner ignition issues or unstable flame. A seized shaft or excessive starting torque can cause the motor to overheat or trip. Leaks may occur at seals, resulting in fuel puddles or a drop in system pressure. Check the filter for debris, verify the shaft rotates freely, and inspect for fuel leaks around the pump body.
All specifications
| Filter area / cross-section | 75/150 cm2/microns |
|---|---|
| Setting range | 5500–21000 mbar |
| Max. starting torque | 0.24 nm |
| Ambient temperature | -20–70 °C |
| Storage temperature | -25–70 °C |
| Fuel temperature | -10–70 °C |
| Fuel | light fuel and kerosene |
| Max. pressure in suction/return line | 4 bar |
| Pump type | gear pump |
| Shaft material | en225 |
| Shaft rotation speed | 1400-3450 min |
| Viscosity range (suction line) | 1.3-75cst(mm2/s) |
| Built-in filter | annular filter |
| System type | single-tube and double-tube |
| Factory set pressure | 7 bar |
| Integrated filter | annular filter |
| Pressure levels | 1 |
| Transport pump | yes |
| Application | small and medium-sized household burners |
| Fuel consumption | 255 l/h |
| Shaft standard | EN225 |
| Filter type | annular filter |
Part numbers
| SKU | 070L3350 |
|---|---|
| Additional article | 327.520.065 |
| Model | RSA60 |