{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Kromschroder Thermo pilot burner ZT40G-100A 84221014

SKU 84221014 Model ZT40G-100A Brand Kromschroder

Photos

no photo yet

Key specifications

Construction typethermoelectric
Country of origingermany
Tube diameter40 mm
Compatible valves11t
Power supplynone
Flame signalcontinuous flame signal
all specifications (6) ↓
649.40 EUR
590.36EUR
in stock · 1

incl. 21% VAT · 487.90 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Kromschroder Thermo pilot burner ZT40G-100A (SKU 84221014) is a thermoelectric pilot burner designed for gas-fired systems. It has a tube diameter of 40 mm and is compatible with the Kromschroder S11T valve. This burner operates without external power supply and provides a continuous flame signal for safety circuits. It is manufactured in Germany.

Further details

Common failure modesblocked gas orifice, distorted flame tube, damaged thermocouple/electrode assembly
Comparison before ordercompare physical length, thread type, electrode configuration with existing unit
Ignition sequencespark from ignition transformer lights pilot flame; flame-sensing device confirms pilot is burning
Replacement factorsburner series, gas flow rate, mounting flange dimensions, flame position
Safety lockoutcontrol box locks out if pilot flame lost

Choosing and fitting

When selecting a pilot burner of this type, verify the tube diameter, length, and mounting configuration against the existing unit. Ensure compatibility with the thermoelectric safety valve (e.g., S11T) and check the gas orifice size for the specific gas type. Compare the flame position relative to the main burner head to ensure proper ignition.

Signs of failure

Common failures include blocked gas orifices, distorted flame tubes, or damaged thermocouples, leading to loss of pilot flame or weak signal. Symptoms may include failure to ignite the main burner, intermittent flame loss, or safety lockout. Check for debris, physical damage, and continuity of the thermocouple circuit.

Fits equipment

Kromschroder S11TKromschroder ZT40G-100A

All specifications

Construction typethermoelectric
Country of origingermany
Tube diameter40 mm
Compatible valves11t
Power supplynone
Flame signalcontinuous flame signal

Part numbers

SKU84221014
Additional article624.205.066
ModelZT40G-100A