Wieland 3-pin male black connector 93.832.3353.0
SKU 93.832.3353.0
Brand Wieland
Photos
no photo yet
Key specifications
| Insulation voltage rating | 250 V |
|---|---|
| Poles / outlets | 3 |
| Conductor cross-section | not specified |
| Pin count | 3 |
| Pitch | not specified |
| Keying | not specified |
| Terminal type | screw |
| Rated current | 16 a |
| Strain relief | special cable clamp |
| Screw connection | reliable and safe |
| Suitable for heavy industrial conditions | yes |
| European quality | yes |
| Matching parameters | pin count, pin pitch, keying |
1.33 EUR
1.21EUR
in stock · 1
incl. 21% VAT · 1.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
Wieland 3-pin male black connector, model 93.832.3353.0, is a screw-terminal plug rated for 250 V and 16 A. It features a special cable clamp for strain relief and is designed for industrial conditions. This connector is used in burner and boiler control circuits to connect components like gas valves, ignition transformers, and fan motors.
Further details
| Application automation ventilation heating | electrical circuits in automation, ventilation, heating and equipment |
|---|---|
| Fault symptoms | intermittent flame signal loss to complete failure to start |
| Inspection advice | check condition of both halves and integrity of crimps |
| Low voltage signals | carry low-voltage signals and mains supply |
| Replacement guidance | ensure corresponding female part same series, correct polarity and keying |
| Selection parameters | connector series, pin count, conductor cross-section, insulation temperature class, cable length, terminal type |
Choosing and fitting
When selecting a replacement connector of this type, ensure the pin count, pin pitch, and keying match the corresponding female part. The terminal type (screw, spring, or crimp) and the conductor cross-section the terminals can accept must also be compatible. Verify the insulation temperature class and cable length if supplied. Always check both halves for correct polarity and keying before installation.
Signs of failure
Connectors of this kind can fail due to corrosion, loose terminals, or bent pins, leading to intermittent signal loss or complete failure to start. Symptoms may include flame signal loss or no power to components. Inspect both connector halves for damage, ensure screws are tight, and verify the integrity of crimps before reassembly.
All specifications
| Insulation voltage rating | 250 V |
|---|---|
| Poles / outlets | 3 |
| Conductor cross-section | not specified |
| Pin count | 3 |
| Pitch | not specified |
| Keying | not specified |
| Terminal type | screw |
| Rated current | 16 a |
| Strain relief | special cable clamp |
| Screw connection | reliable and safe |
| Suitable for heavy industrial conditions | yes |
| European quality | yes |
| Matching parameters | pin count, pin pitch, keying |
Part numbers
| SKU | 93.832.3353.0 |
|---|---|
| Additional article | 980.640.012 |