Fema Pressure switch DWR6

SKU DWR6 Brand Fema

Photos

Key specifications

Setting range500–6000 mbar
Protection class (IP)IP54
Setting range0.5–6 bar
Switching differential0.15 bar
Maximum working pressure16 bar
Switching elementsingle-pole changeover switch
Operating principlemechanical pressure switch
Mediumair or non-combustible gases
Operating positionvertical
Adjustment methodadjustable from outside with screwdriver
Maximum working pressure16
Switching differential150 mbar
all specifications (12) ↓
1432.54 EUR
1302.31EUR
in stock · 1

incl. 21% VAT · 1076.29 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Fema DWR6 is a mechanical pressure switch designed for air or non-combustible gases. It has a setting range of 0.5 to 6 bar and a switching differential of 0.15 bar. The maximum working pressure is 16 bar. The switch features a single-pole changeover switching element and is protected to IP54. Adjustment is performed externally with a screwdriver, and the recommended operating position is vertical.

Further details

Body Materialseawater-resistant die cast aluminium gd al si 12
Connection ThreadG 1/2 external, G 1/4 internal
Contact arrangementSingle-pole changeover switch
Degree of protectionIP 54, in vertical position
MountingDirectly on the pressure line (pressure gauge connection) or on a flat surface with two 4 mm Ø screws
Switching deviceRobust housing (200) made of seawater-resistant die cast aluminium GD Al Si 12
Switching pressureAdjustable from outside with screwdriver

Choosing and fitting

Pressure switches of this type are selected based on the required setting range, switching differential, and maximum working pressure. The medium must be compatible with the switch materials. Installation can be direct on the pressure line or on a flat surface using two screws. Ensure the switch is mounted in the specified operating position to maintain the stated protection class.

Signs of failure

Common failure modes for mechanical pressure switches include leakage, contact welding, or drift in the setpoint. Symptoms may include failure to switch, erratic operation, or the system not responding to pressure changes. Check for physical damage, contamination, and verify the setpoint with a calibrated gauge.

All specifications

Setting range500–6000 mbar
Protection class (IP)IP54
Setting range0.5–6 bar
Switching differential0.15 bar
Maximum working pressure16 bar
Switching elementsingle-pole changeover switch
Operating principlemechanical pressure switch
Mediumair or non-combustible gases
Operating positionvertical
Adjustment methodadjustable from outside with screwdriver
Maximum working pressure16
Switching differential150 mbar

Part numbers

SKUDWR6
Additional article444.676.006