Fema Pressure switch DWR6
SKU DWR6
Brand Fema
Photos
Key specifications
| Setting range | 500–6000 mbar |
|---|---|
| Protection class (IP) | IP54 |
| Setting range | 0.5–6 bar |
| Switching differential | 0.15 bar |
| Maximum working pressure | 16 bar |
| Switching element | single-pole changeover switch |
| Operating principle | mechanical pressure switch |
| Medium | air or non-combustible gases |
| Operating position | vertical |
| Adjustment method | adjustable from outside with screwdriver |
| Maximum working pressure | 16 |
| Switching differential | 150 mbar |
1432.54 EUR
1302.31EUR
in stock · 1
incl. 21% VAT · 1076.29 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Fema DWR6 is a mechanical pressure switch designed for air or non-combustible gases. It has a setting range of 0.5 to 6 bar and a switching differential of 0.15 bar. The maximum working pressure is 16 bar. The switch features a single-pole changeover switching element and is protected to IP54. Adjustment is performed externally with a screwdriver, and the recommended operating position is vertical.
Further details
| Body Material | seawater-resistant die cast aluminium gd al si 12 |
|---|---|
| Connection Thread | G 1/2 external, G 1/4 internal |
| Contact arrangement | Single-pole changeover switch |
| Degree of protection | IP 54, in vertical position |
| Mounting | Directly on the pressure line (pressure gauge connection) or on a flat surface with two 4 mm Ø screws |
| Switching device | Robust housing (200) made of seawater-resistant die cast aluminium GD Al Si 12 |
| Switching pressure | Adjustable from outside with screwdriver |
Choosing and fitting
Pressure switches of this type are selected based on the required setting range, switching differential, and maximum working pressure. The medium must be compatible with the switch materials. Installation can be direct on the pressure line or on a flat surface using two screws. Ensure the switch is mounted in the specified operating position to maintain the stated protection class.
Signs of failure
Common failure modes for mechanical pressure switches include leakage, contact welding, or drift in the setpoint. Symptoms may include failure to switch, erratic operation, or the system not responding to pressure changes. Check for physical damage, contamination, and verify the setpoint with a calibrated gauge.
All specifications
| Setting range | 500–6000 mbar |
|---|---|
| Protection class (IP) | IP54 |
| Setting range | 0.5–6 bar |
| Switching differential | 0.15 bar |
| Maximum working pressure | 16 bar |
| Switching element | single-pole changeover switch |
| Operating principle | mechanical pressure switch |
| Medium | air or non-combustible gases |
| Operating position | vertical |
| Adjustment method | adjustable from outside with screwdriver |
| Maximum working pressure | 16 |
| Switching differential | 150 mbar |
Part numbers
| SKU | DWR6 |
|---|---|
| Additional article | 444.676.006 |