{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Kromschroder Differential pressure switch DG500U-3 84447550

SKU 84447550 Model DG500U-3 Brand Kromschroder

Photos

Key specifications

Setting range100–500 mbar
Protection class (IP)IP 65
Body materialglass fibre reinforced PBT plastic
Sensing elementNBR diaphragm
Switching elementmicroswitch with switching contact
Operating principlediaphragm pressure switch
Safety class1
Line entrance threadM16 x 1.5
Switching with rising pressureyes
Trigger level adjustmenthandwheel
Monitoring pressure changesyes
Gas sensoryes
Switching contactmicroswitch with switching contact
Maintenance intervalannual
Post-maintenance leak checkyes
Diaphragm pressure switchyes
Construction typediaphragm pressure switch
Diaphragm materialNBR
Lower housing materialAlSi 12
Silicone-freeyes
Low gas releaseyes
all specifications (21) ↓
203.90 EUR
185.36EUR
in stock · 4

incl. 21% VAT · 153.19 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Kromschroder DG500U-3 is a diaphragm pressure switch with a pressure range of 100–500 mbar. It monitors pressure changes in gases or air, switching a microswitch contact when the setpoint is reached. The trigger level is adjusted via a handwheel. The device features a glass fibre reinforced PBT plastic housing with an AlSi 12 lower section, an NBR diaphragm, and is silicone-free. It has an IP 65 protection class and a safety class of 1, with an M16 x 1.5 line entrance thread.

Further details

Electrical Connectionscrew terminals and M16 cable gland

Choosing and fitting

When selecting a replacement pressure switch of this type, ensure the pressure range, switching function (rising or falling pressure), and electrical connection (screw terminals, cable gland size) match the original. The mounting orientation and process connection thread must also be compatible. Verify the medium compatibility and temperature limits for the application.

Signs of failure

Common failure modes include diaphragm rupture or leakage, leading to loss of pressure sensing or false switching. The switch may fail to trigger at the setpoint or stick in one position. Check for leaks around the diaphragm and housing, and verify the microswitch operation with a multimeter.

All specifications

Setting range100–500 mbar
Protection class (IP)IP 65
Body materialglass fibre reinforced PBT plastic
Sensing elementNBR diaphragm
Switching elementmicroswitch with switching contact
Operating principlediaphragm pressure switch
Safety class1
Line entrance threadM16 x 1.5
Switching with rising pressureyes
Trigger level adjustmenthandwheel
Monitoring pressure changesyes
Gas sensoryes
Switching contactmicroswitch with switching contact
Maintenance intervalannual
Post-maintenance leak checkyes
Diaphragm pressure switchyes
Construction typediaphragm pressure switch
Diaphragm materialNBR
Lower housing materialAlSi 12
Silicone-freeyes
Low gas releaseyes

Part numbers

SKU84447550
Additional article624.214.030
ModelDG500U-3