Key specifications
| Connection thread | M16 x 1.5 |
|---|---|
| Body material | glass fibre reinforced PBT plastic |
| Sensing element | diaphragm |
| Electrical connection | screw terminals |
| Safety class | 1 |
| Component type | pressure switch |
| Lower housing material | AlSi 12 |
| Silicone-free | yes |
| Low gas release | yes |
| Line entrance thread | M16 x 1.5 |
| Screw terminals | yes |
| Diaphragm pressure switch | yes |
| Construction type | diaphragm pressure switch |
204.71 EUR
186.10EUR
in stock · 3
incl. 21% VAT · 153.80 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Kromschroder DG50U-3T2 pressure switch (SKU 84447387) is a diaphragm-type pressure switch designed for monitoring pressure changes in gas or air environments. It features a glass fibre reinforced PBT plastic housing with low gas release, and the lower housing section is made of AlSi 12. The switch is silicone-free and has a connection thread of M16 x 1.5, with electrical connection via screw terminals. It is classified under safety class 1 and is suitable for use with natural gas, town gas, LPG (gaseous), flue gas, biogas (max. 0.1% by vol. H2S), and air.
Choosing and fitting
When selecting a replacement pressure switch of this type, ensure the connection thread (e.g., M16 x 1.5) matches the existing line entrance, and verify the electrical connection type (screw terminals) is compatible. The switch should be chosen based on the required pressure range and the medium (gas or air) it will monitor. Installation involves connecting the pressure line to the switch and wiring the screw terminals according to the system's electrical specifications.
Signs of failure
Common failure modes for diaphragm pressure switches include diaphragm rupture or leakage, which can cause the switch to fail to detect pressure changes or to trigger false alarms. Symptoms may include the burner not starting, unexpected shutdowns, or erratic operation. Check the diaphragm for damage, verify the pressure setting, and ensure the electrical connections are secure.
All specifications
| Connection thread | M16 x 1.5 |
|---|---|
| Body material | glass fibre reinforced PBT plastic |
| Sensing element | diaphragm |
| Electrical connection | screw terminals |
| Safety class | 1 |
| Component type | pressure switch |
| Lower housing material | AlSi 12 |
| Silicone-free | yes |
| Low gas release | yes |
| Line entrance thread | M16 x 1.5 |
| Screw terminals | yes |
| Diaphragm pressure switch | yes |
| Construction type | diaphragm pressure switch |
Part numbers
| SKU | 84447387 |
|---|---|
| Additional article | 624.214.205 |
| Model | DG50U-3T2 |