Kromschroder Gas pressure switch DG50U-6T 84447353
SKU 84447353
Model DG50U-6T
Brand Kromschroder
Photos
Key specifications
| Setting range | 2.5–50 mbar |
|---|---|
| Connection thread | M16 x 1.5 |
| Body material | glass fibre reinforced PBT plastic |
| Sensing element | NBR diaphragm |
| Operating principle | mechanical pressure switch |
| Electrical connection | 4-pin plug with socket |
| Safety class | 1 |
| Component type | pressure switch |
| Lower housing material | AlSi 12 |
| Silicone-free | yes |
| Low gas release | yes |
| Line entrance thread | M16 x 1.5 |
| Screw terminals | yes |
| Switching with rising pressure | yes |
| Post-maintenance leak check | required |
| Diaphragm pressure switch | yes |
| Construction type | diaphragm pressure switch |
| Supply voltage | 220–240 V |
287.79 EUR
261.63EUR
in stock · 2
incl. 21% VAT · 216.22 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Kromschroder DG50U-6T is a diaphragm pressure switch with a pressure range of 2.5–50 mbar. It operates on a mechanical principle and features a glass fibre reinforced PBT plastic body with a lower housing of AlSi 12. The sensing element is an NBR diaphragm, and the switch is silicone-free with low gas release. It has a 4-pin plug with socket for electrical connection, screw terminals, and a connection thread of M16 x 1.5. The switch is designed for rising pressure and is safety class 1, with a supply voltage of 220–240 V.
Choosing and fitting
When selecting a pressure switch of this type, ensure the pressure range, connection thread, and electrical specifications match the system requirements. The switch must be compatible with the medium and ambient conditions. Installation involves connecting the pressure line to the appropriate port and wiring the electrical connections according to the schematic. After installation, a leak check is required to ensure proper sealing.
Signs of failure
Common failures include diaphragm rupture or leakage, leading to loss of pressure sensing or false switching. Electrical contact issues may cause intermittent operation or failure to switch. Symptoms on the equipment include burner lockout, erratic pressure readings, or failure to start. Regular functional checks and leak tests are recommended to detect issues early.
All specifications
| Setting range | 2.5–50 mbar |
|---|---|
| Connection thread | M16 x 1.5 |
| Body material | glass fibre reinforced PBT plastic |
| Sensing element | NBR diaphragm |
| Operating principle | mechanical pressure switch |
| Electrical connection | 4-pin plug with socket |
| Safety class | 1 |
| Component type | pressure switch |
| Lower housing material | AlSi 12 |
| Silicone-free | yes |
| Low gas release | yes |
| Line entrance thread | M16 x 1.5 |
| Screw terminals | yes |
| Switching with rising pressure | yes |
| Post-maintenance leak check | required |
| Diaphragm pressure switch | yes |
| Construction type | diaphragm pressure switch |
| Supply voltage | 220–240 V |
Part numbers
| SKU | 84447353 |
|---|---|
| Additional article | 624.214.153 |
| Model | DG50U-6T |