Kromschroder Gas pressure switch DG60VC5-5W 84444625
SKU 84444625
Model DG60VC5-5W
Brand Kromschroder
Photos
no photo yet
Key specifications
| Setting range | 0.2–3.3 mbar |
|---|---|
| Protection class (IP) | II |
| Body material | glass fibre reinforced PBT plastic |
| Electrical connection | screw terminals |
| Medium | air or flue gas |
| Weight | 150 g |
| Low gas release | yes |
| Designed lifetime | 10 years |
| Diaphragm system | tempered LSR diaphragm |
| Micro switch standard | EN 61058-1 |
| Strain relief torque | 65 Ncm |
| Standards | EN 13611:2015+AC:2016 and EN 1854:2010 |
| Strain relief facility | 65 Ncm |
| Housing with tube connection and hand wheel | yes |
| EN 1854 | 2010 |
| Construction type | diaphragm pressure switch |
97.03 EUR
88.21EUR
in stock · 1
incl. 21% VAT · 72.90 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Kromschroder DG60VC5-5W gas pressure switch (SKU 84444625) is a diaphragm-type pressure switch designed for monitoring air or flue gas pressure in burner and boiler systems. It has an adjustable pressure range of 0.2–3.3 mbar and features a tempered LSR diaphragm system. The housing is made of glass fibre reinforced PBT plastic with low gas release, and it includes a tube connection and hand wheel. Electrical connection is via screw terminals, and the micro switch complies with EN 61058-1. The switch is protection class II, weighs 150 g, and has a designed lifetime of 10 years. It meets standards EN 13611:2015+AC:2016 and EN 1854:2010, with type designation CE-0085AP0466.
Choosing and fitting
When selecting a replacement pressure switch of this type, verify the required pressure range, medium compatibility (air or flue gas), and electrical connection method. Ensure the switch's set point range covers the system's operating pressure. Mounting must accommodate the tube connection and hand wheel; check the physical dimensions and thread type. The electrical connection uses screw terminals, so confirm voltage and current ratings match the circuit. Also, consider the protection class and ambient temperature limits for the installation environment.
Signs of failure
Common failure modes for diaphragm pressure switches include diaphragm rupture or leakage, leading to loss of pressure sensing or false triggering. Symptoms may include burner lockout, erratic operation, or failure to detect pressure changes. Check for visible damage to the housing or diaphragm, and verify the switch's set point with a manometer. Also, inspect the electrical contacts for wear or corrosion, which can cause intermittent signals.
All specifications
| Setting range | 0.2–3.3 mbar |
|---|---|
| Protection class (IP) | II |
| Body material | glass fibre reinforced PBT plastic |
| Electrical connection | screw terminals |
| Medium | air or flue gas |
| Weight | 150 g |
| Low gas release | yes |
| Designed lifetime | 10 years |
| Diaphragm system | tempered LSR diaphragm |
| Micro switch standard | EN 61058-1 |
| Strain relief torque | 65 Ncm |
| Standards | EN 13611:2015+AC:2016 and EN 1854:2010 |
| Strain relief facility | 65 Ncm |
| Housing with tube connection and hand wheel | yes |
| EN 1854 | 2010 |
| Construction type | diaphragm pressure switch |
Part numbers
| SKU | 84444625 |
|---|---|
| Additional article | 624.214.230 |
| Model | DG60VC5-5W |
| Type designation | CE-0085AP0466 |