EBM PAPST Tangential fan QL3/3000A2-2118LH-455ca 55443.12000
SKU 55443.12000
Model QL3/3000A2-2118LH-455ca
Brand EBM PAPST
Photos
Key specifications
| Length | 302 mm |
|---|---|
| Width | 50 mm |
| Air flow | 80 m3/h |
| Current consumption | 0.04 A |
| Rotation speed | 2580 rpm |
| Application type | combustion air supply |
| Control Mode | Mains, PWM, or 0-10 V |
| Housing type | tangential fan |
| Electrical connection | Electrical communication with control board |
159.72 EUR
145.20EUR
in stock · 1
incl. 21% VAT · 120.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This is a tangential fan from EBM PAPST for combustion air supply. It has a housing size of 302 mm by 50 mm, delivers an air flow of 80 m³/h, and consumes 0.04 A at a rotation speed of 2580 rpm. The fan is controlled by mains, PWM, or a 0-10 V signal and communicates electrically with the control board.
Further details
| Air pressure verification | Air pressure switch verifies sufficient airflow before ignition |
|---|---|
| Primary application in burner systems | Pre-purge phase air clearing, combustion control, flue gas exhaust |
| Speed modulation for air-fuel ratio | Speed directly sets firing rate; burner control varies speed |
Choosing and fitting
When replacing a fan of this type, verify the direction of rotation, outlet orientation, impeller diameter, voltage rating, control mode, and flange pattern to ensure physical and functional fit. The fan speed directly sets the firing rate in modulating systems, so the replacement must match the required air flow and pressure of the burner. Ensure the control mode (mains, PWM, or 0-10 V) is compatible with the burner control.
Signs of failure
Typical failure modes of such fans include worn bearings causing noise or vibration, imbalance from deposits on the impeller, a defective capacitor on single-phase models, and speed feedback errors that the boiler reports as an airflow fault. If the fan fails, the burner may not start or may shut down during operation. Check the impeller for deposits, listen for unusual noise, and verify the capacitor and speed feedback signal.
All specifications
| Length | 302 mm |
|---|---|
| Width | 50 mm |
| Air flow | 80 m3/h |
| Current consumption | 0.04 A |
| Rotation speed | 2580 rpm |
| Application type | combustion air supply |
| Control Mode | Mains, PWM, or 0-10 V |
| Housing type | tangential fan |
| Electrical connection | Electrical communication with control board |
Part numbers
| SKU | 55443.12000 |
|---|---|
| Additional article | 377.145.074 |
| Model | QL3/3000A2-2118LH-455ca |