{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

EBM PAPST Tangential fan QL3/3000A2-2118LH-455cx 55443.12001

SKU 55443.12001 Model QL3/3000A2-2118LH-455cx Brand EBM PAPST

Photos

Key specifications

Length380 mm
Width302.6 mm
Current consumption0.8 A
Air flow80 m3/h
Application typecombustion air supply
Housing typetangential
Rated voltage12 v
Input power10 W
Overall dimensions302.6x18
Catalogue article numbers55443.12001, 377.145.075
all specifications (10) ↓
159.72 EUR
145.20EUR
in stock · 1

incl. 21% VAT · 120.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The EBM PAPST QL3/3000A2-2118LH-455cx is a tangential fan designed for combustion air supply in burners and boilers. It operates at a rated voltage of 12 V, consumes 0.8 A, and has an input power of 10 W. The fan delivers an air flow of 80 m³/h and has overall dimensions of 302.6x18 mm, with a length of 380 mm and width of 302.6 mm. This model is identified by SKU 55443.12001 and article number 377.145.075.

Further details

Control Modemains on/off, pwm, or 0-10 v signal

Choosing and fitting

When selecting a replacement tangential fan of this type, ensure the voltage and control mode (mains on/off, PWM, or 0-10 V signal) match the burner control board. Verify the air flow and static pressure requirements, as well as the direction and orientation of the air outlet. The flange pattern and mounting arrangement must be compatible with the existing housing. Measure the impeller diameter and overall dimensions to confirm fit.

Signs of failure

Common failure modes for tangential fans include worn bearings causing noise or seizing, imbalance from deposits on impeller blades, and speed feedback errors that the boiler interprets as an airflow fault, leading to lockout. In single-phase motors, a failed capacitor can also cause failure. Check for unusual noises, vibration, or error codes related to airflow.

All specifications

Length380 mm
Width302.6 mm
Current consumption0.8 A
Air flow80 m3/h
Application typecombustion air supply
Housing typetangential
Rated voltage12 v
Input power10 W
Overall dimensions302.6x18
Catalogue article numbers55443.12001, 377.145.075

Part numbers

SKU55443.12001
Additional article377.145.075
ModelQL3/3000A2-2118LH-455cx