Brahma Immersion temperature sensor 18200499
SKU 18200499
Brand Brahma
Photos
Key specifications
| Length | 40 mm |
|---|---|
| Width | 20 mm |
| Height | 15 mm |
| Control type | NTC |
| Safety feature | overheating protection |
| Connection | G1/8 |
| Version | ch15 |
| Thermostat function | reports temperature readings |
| Probe form type | immersion temperature sensor |
| Net weight | 0.012 kg |
| Gross weight | 0.017 kg |
13.57 EUR
12.34EUR
in stock · 1
incl. 21% VAT · 10.20 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This is an immersion temperature sensor from Brahma, type designation ST09 FE M/1 G1/8 CH15 (SKU 18200499). It is an NTC sensor that measures the temperature of the heat transfer fluid in heating and water heating equipment. The sensor reports temperature readings to the control board, enabling modulation and overheating protection. It has a G1/8 connection, version ch15, and dimensions of 40 x 20 x 15 mm. Net weight is 0.012 kg, gross weight 0.017 kg.
Further details
| Application area | heating and hot water supply systems |
|---|---|
| Application type | floor-standing boilers, wall-mounted boilers, boilers with DHW tank, storage water heaters, instantaneous water heaters |
Choosing and fitting
Replacement immersion NTC sensors are selected by their resistance characteristic at a reference temperature (typically 10 kΩ or 12 kΩ at 25 °C), probe form, cable length, and connector type. The probe form must match the installation point: immersion probes need a correctly sized pocket, while clamp-on probes require good thermal contact with the pipe. Before ordering, verify the electrical characteristic and mechanical fit against the existing part. For sensors that act on a switching point, the reset type (auto or manual) must also be considered.
Signs of failure
Common failure modes for NTC temperature sensors include a drifting resistance characteristic, which causes incorrect modulation, a broken cable, or poor contact between a clamp-on probe and the pipe surface. When a sensor fails, the boiler may modulate incorrectly, fail to reach setpoint, or show erroneous temperature readings. Check the resistance at the reference temperature and inspect the cable and mounting for physical damage or poor contact.
All specifications
| Length | 40 mm |
|---|---|
| Width | 20 mm |
| Height | 15 mm |
| Control type | NTC |
| Safety feature | overheating protection |
| Connection | G1/8 |
| Version | ch15 |
| Thermostat function | reports temperature readings |
| Probe form type | immersion temperature sensor |
| Net weight | 0.012 kg |
| Gross weight | 0.017 kg |
Part numbers
| SKU | 18200499 |
|---|---|
| Additional article | 246.220.109 |
| Type designation | ST09 FE M/1 G1/8 CH15 |