{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

De Dietrich NTC temperature sensor S101003

SKU S101003 Brand De Dietrich

Photos

no photo yet

Key specifications

Sensor typeNTC
Mounting typesurface-mounted
Wire connector2-wire connector
Housing materialheat-resistant plastic
Installationeasy to replace and install
all specifications (5) ↓
49.96 EUR
45.42EUR
in stock · 2

incl. 21% VAT · 37.54 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The De Dietrich NTC temperature sensor S101003 is a surface-mounted thermistor designed for use in De Dietrich boilers. It monitors the heat carrier temperature and opens the circuit to shut off the gas valve if the temperature exceeds safe limits, preventing overheating. The sensor features a 2-wire connector and a heat-resistant plastic housing, making it easy to replace and install. It is compatible with a range of De Dietrich models including C 230 ECO, C 310 / 610 ECO, C 210 ECO, GT 300, DTG 230 ECONOX, MC 65 / MC 90, M 40-S, DTG 320 ECONOX, GT 430, DTG 120 NEZ DIEMATIC, GTE 500, G 300 S, DTG 350 NEZ/DIEMATIC, and DOMOGAS DGXE 14-47 (up to 04.95).

Further details

Compatible boilersDe Dietrich C 230 ECO, C 310 / 610 ECO, C 210 ECO, GT 300, DTG 230 ECONOX, MC 65 / MC 90, M 40-S, DTG 320 ECONOX, GT 430, DTG 120 NEZ Diematic, GTE 500, and burner systems DGXE 14-47 (before 1995)
Safety functionopens circuit, shuts off gas valve, prevents overheating

Choosing and fitting

When selecting a replacement temperature sensor of this type, ensure the sensor type (NTC) and resistance characteristics match the boiler's control board. Verify the mounting form (surface-mounted) and connector type (2-wire) are compatible with the existing wiring. Compare the physical dimensions and housing material to ensure proper fit and heat resistance. Installation typically involves disconnecting the old sensor, connecting the new one via the 2-wire connector, and securing it in place.

Signs of failure

Common failure modes for NTC temperature sensors include open or short circuits, leading to incorrect temperature readings or no signal. Symptoms may include the boiler failing to start, frequent cycling, or error codes related to temperature sensing. Check the sensor's resistance with a multimeter at ambient temperature and compare to expected values; also inspect wiring and connections for damage or corrosion.

Fits equipment

De Dietrich C 230 ECODe Dietrich C 310 / 610 ECODe Dietrich C 210 ECODe Dietrich GT 300De Dietrich DTG 230 ECONOXDe Dietrich MC 65 / MC 90De Dietrich M 40-SDe Dietrich DTG 320 ECONOXDe Dietrich GT 430De Dietrich DTG 120 NEZ DIEMATICDe Dietrich GTE 500De Dietrich G 300 SDe Dietrich DTG 350 NEZ/DIEMATICDe Dietrich DOMOGAS DGXE 14-47 (up to 04.95)

All specifications

Sensor typeNTC
Mounting typesurface-mounted
Wire connector2-wire connector
Housing materialheat-resistant plastic
Installationeasy to replace and install

Part numbers

SKUS101003
Additional article336.220.004