{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

ACV Slow-blow fuse 5476C011

SKU 5476C011 Brand ACV

Photos

Key specifications

Rated current12.5 a
Fuse size6.3 mm
Fuse speedslow-blow (time-lag)
Application boilersACV boilers
all specifications (4) ↓
11,26 EUR
10,24EUR
in stock · 1

incl. 21% VAT · 8,46 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Descripción

The ACV Slow-blow fuse 5476C011 is a 12.5 A, 6.3 mm fuse with a slow-blow (time-lag) characteristic, designed for use in ACV boilers. It fits models including the HeatMaster 45 TC Smart ME Prestige Solo MK2 and HeatMaster 45 TC. This fuse protects control boards, ignition transformers, and low-voltage circuits from overcurrent and short circuits. Its slow-blow action tolerates brief inrush currents during start-up, preventing nuisance trips.

Información adicional

Advantagesfast response to voltage surges, reliable component protection, factory-approved original part
Protection functionprotects control board, ignition transformer, and low-voltage circuits against overcurrent and short circuits
Used in modelsHeatmaster 45 TC Smart Me Prestige Solo MK2

Elección y montaje

When selecting a fuse of this type, match the physical dimensions (e.g., 6.3 x 32 mm), current rating, and speed (slow-blow) to the original. Verify the voltage rating on the fuse body is at least the circuit voltage. Never use a higher current rating or faster speed, as this compromises protection. Always investigate the cause of a blown fuse before replacement.

Señales de avería

A blown fuse of this kind typically results from a shorted component or failing transformer, causing the boiler to lose power to protected circuits. Symptoms include the boiler failing to start, control board not powering up, or ignition transformer not operating. Check the fuse continuity and inspect for visible damage or discoloration.

Compatible con

ACV HeatMaster 45 TC Smart ME Prestige Solo MK2 HeatMaster 45 TCACV Heatmaster 45 TC Smart Me Prestige Solo MK2

Todas las características

Rated current12.5 a
Fuse size6.3 mm
Fuse speedslow-blow (time-lag)
Application boilersACV boilers

Part numbers

SKU5476C011
Additional article129.595.001