Honeywell Gas boiler control unit S4560A1008U
SKU S4560A1008U
Model S4560A1008
Brand Honeywell
Photos
Key specifications
| Cycle type | intermittent |
|---|---|
| Flame detector type | flame sensor rod |
| Frequency | 50 Hz |
| Ignition type | direct |
| Application | atmospheric gas burners |
| Safety standard | EN 298 |
| Supply voltage | 220–240 V |
| Fuel | gas |
| TC test period tP | 2.5 s |
| Connector type | Molex 3001 multi-edge connector |
| Behaviour in the event of flame failure during operation | repeats ignition sequence |
| Flame relay output | yes |
| Fan support | yes |
| Internal ignition | no |
| Lockout type | non-volatile blocking |
| Maintenance free | yes |
| Power consumption | 10 W |
| Reset button type | external or internal reset button |
| Blocking in absence of ether | yes |
| Safety feature | Manual reset lockout |
| Safety time | 10 s |
| Time ts | 10 s |
| Protection class (IP) | IP40 |
| Restart behavior | repeats ignition sequence |
| Reset wait time | 15 s |
| Blocking during flame simulation | yes |
| Gas valve + GPS connection | yes |
| Input signal protection from reset | yes |
| Quick launch option | yes |
| LPG valve support | yes |
| Maximum thermal relay required | yes |
| Shielded ignition cables required | yes |
| Length | 137 mm |
| Width | 86 mm |
| Height | 49 mm |
| EN 298 compliance | yes |
| Application type | atmospheric gas burners |
| Flame monitoring | flame sensor rod |
| Waiting time | 0 s |
| Mounting hole diameter | 4.5 mm |
| Spark terminal size | 2.8 mm |
| Flame extinguisher tip size | 6.3 mm |
| External fuse | yes |
| Rigid locking | yes |
| High temperature effect | shortens service life |
| Gas pressure monitoring | yes |
| TTB relay reset required | yes |
419.27 EUR
381.15EUR
in stock · 1
incl. 21% VAT · 315.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell S4560A1008U is a gas boiler control unit for atmospheric gas burners. It operates in intermittent cycle mode with direct ignition and flame monitoring via a sensor rod. The unit conforms to EN 298 and features a non-volatile lockout with manual reset. It operates at 220–240 V, 50 Hz, with a power consumption of 10 W and a safety time of 10 s. The control box has a Molex 3001 multi-edge connector, supports a fan, and is rated IP40. It is maintenance-free and requires external fuses and a thermal relay.
Choosing and fitting
Control boxes of this type are selected by matching the supply voltage, frequency, safety time, and connector configuration of the existing installation. Before ordering, compare the mounting dimensions and terminal sizes with the original unit. During installation, provide external fuses for safety and place the controller away from heat and radiation. The overall enclosure protection must be at least IP40, and spark ignition cables must be shielded. These controllers have no user-serviceable parts; do not attempt internal repairs.
Signs of failure
Typical failure of these control units is a lockout when the flame is not detected within the safety time, often caused by a dirty or misaligned flame sensor rod. If the flame goes out during operation, the unit repeats the ignition sequence. Lockout is non-volatile and requires manual reset via the external or internal reset button. If the first reset fails, wait at least 15 seconds before again attempting reset.
All specifications
| Cycle type | intermittent |
|---|---|
| Flame detector type | flame sensor rod |
| Frequency | 50 Hz |
| Ignition type | direct |
| Application | atmospheric gas burners |
| Safety standard | EN 298 |
| Supply voltage | 220–240 V |
| Fuel | gas |
| TC test period tP | 2.5 s |
| Connector type | Molex 3001 multi-edge connector |
| Behaviour in the event of flame failure during operation | repeats ignition sequence |
| Flame relay output | yes |
| Fan support | yes |
| Internal ignition | no |
| Lockout type | non-volatile blocking |
| Maintenance free | yes |
| Power consumption | 10 W |
| Reset button type | external or internal reset button |
| Blocking in absence of ether | yes |
| Safety feature | Manual reset lockout |
| Safety time | 10 s |
| Time ts | 10 s |
| Protection class (IP) | IP40 |
| Restart behavior | repeats ignition sequence |
| Reset wait time | 15 s |
| Blocking during flame simulation | yes |
| Gas valve + GPS connection | yes |
| Input signal protection from reset | yes |
| Quick launch option | yes |
| LPG valve support | yes |
| Maximum thermal relay required | yes |
| Shielded ignition cables required | yes |
| Length | 137 mm |
| Width | 86 mm |
| Height | 49 mm |
| EN 298 compliance | yes |
| Application type | atmospheric gas burners |
| Flame monitoring | flame sensor rod |
| Waiting time | 0 s |
| Mounting hole diameter | 4.5 mm |
| Spark terminal size | 2.8 mm |
| Flame extinguisher tip size | 6.3 mm |
| External fuse | yes |
| Rigid locking | yes |
| High temperature effect | shortens service life |
| Gas pressure monitoring | yes |
| TTB relay reset required | yes |
Part numbers
| SKU | S4560A1008U |
|---|---|
| Additional article | 534.412.141 |
| Model | S4560A1008 |
| Type designation | S4560B1089U |