Honeywell Gas boiler control unit S4565AD1017U
SKU S4565AD1017U
Model S4565AD1017
Brand Honeywell
Photos
Key specifications
| Safety standard | EN 298; EN 60730-1 |
|---|---|
| Ambient temperature | -15–60 °C |
| Frequency | 50 Hz |
| TC test period tP | 0 s |
| Application | DBI or IP |
| Supply voltage | 220–240 V |
| Fuel | Gas |
| Certification | European standards |
| Installation position | any |
| Mounting position | any |
| Supported ignition systems | DBI and IP |
| Combustion type | Atmospheric |
| Air detection blocking | Shut-off without air access |
| Ignition configuration | Round, closed loop, AC/DC |
| Safety time | 5 s |
| Enclosure type | New (N) or Old (O) |
| connection_type | Molex 3003 connector |
| Connector type | Molex 3003 connector |
| Fan voltage | 220–240 V |
| Fan current | 1 A |
| Spark frequency | 40 Hz |
| Minimum open spark voltage | 20 kV |
| Reset wait time | 15 s |
| Waiting time | 30 s |
| Increased sparking time | 5 s |
| Constant alarm | 1 mA |
| Ignition and flame extinguishing | Separate (S) or combined (C) |
| Flame sensor | Phase (P) or phase-vertical (N) |
| Flame power | PDT(s), PDT(d) or OP |
| Connector on top | Yes |
| Gas regulator compatibility | VK41 series |
| Control system | CVI |
| Direct flame interaction | No |
| Reset button type | Own or external button |
| Reset method | Press own or external button |
| Lockout type | Non-volatile (N) or unstable (V) |
| Blocking mode | Non-volatile or unstable |
| Reset/alarm mode | Integral (I) or remote (R) |
| Electromagnetic filter | Yes |
| Integrated protection | Yes |
| EN 298 compliance | Yes |
| Compatible gas valves | VK4100 series |
| Flame monitoring | Yes |
| Power consumption | 4 W |
| Self-test time | 0 s |
167.08 EUR
151.89EUR
in stock · 2
incl. 21% VAT · 125.53 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell S4565AD1017U is a gas boiler control unit (control box) for atmospheric gas combustion systems. It supports DBI and IP ignition systems and is compatible with Honeywell VK41 and VK4100 series gas regulators and valves. The unit operates on 220–240 V AC, 50 Hz, with a power consumption of 4 W, providing a spark frequency of 40 Hz at 20 kV and a safety time of 5 s. It is rated for ambient temperatures between -15 °C and 60 °C and conforms to EN 298 and EN 60730-1 standards. The control unit features a Molex 3003 connector, an electromagnetic filter, and can be reset via an integral or remote button. It also includes flame monitoring and integrated protection.
Further details
| Controlled Components | Flame and gas flow for main and pilot burners |
|---|---|
| Electrical Integration | Can be directly connected to electrical circuit of gas regulator |
| Housing variant | Standard or flame retarding / IPX4 |
| Humidity Max | 90% r.h. (at 40°C) without condensation |
| Ignition Type | Direct spark ignition (DBI) or pilot ignition (IP) |
Choosing and fitting
Control units of this type are selected based on the gas valve series (VK41 or VK4100) and the supply voltage (220–240 V AC, 50 Hz). The electrical connection uses a Molex 3003/3001 connector, so the harness plug must match. The unit can be mounted in any position; however, the top-mounted connector should remain accessible. Before ordering, confirm that the ignition system type (DBI or IP) and the flame sensor configuration (phase or phase-vertical) are compatible with the existing setup.
Fits equipment
Honeywell VK41
Honeywell VK41 seriesHoneywell VK4100 seriesHoneywell VK41 series gas regulatorsHoneywell VK4100 series gas valves
All specifications
| Safety standard | EN 298; EN 60730-1 |
|---|---|
| Ambient temperature | -15–60 °C |
| Frequency | 50 Hz |
| TC test period tP | 0 s |
| Application | DBI or IP |
| Supply voltage | 220–240 V |
| Fuel | Gas |
| Certification | European standards |
| Installation position | any |
| Mounting position | any |
| Supported ignition systems | DBI and IP |
| Combustion type | Atmospheric |
| Air detection blocking | Shut-off without air access |
| Ignition configuration | Round, closed loop, AC/DC |
| Safety time | 5 s |
| Enclosure type | New (N) or Old (O) |
| connection_type | Molex 3003 connector |
| Connector type | Molex 3003 connector |
| Fan voltage | 220–240 V |
| Fan current | 1 A |
| Spark frequency | 40 Hz |
| Minimum open spark voltage | 20 kV |
| Reset wait time | 15 s |
| Waiting time | 30 s |
| Increased sparking time | 5 s |
| Constant alarm | 1 mA |
| Ignition and flame extinguishing | Separate (S) or combined (C) |
| Flame sensor | Phase (P) or phase-vertical (N) |
| Flame power | PDT(s), PDT(d) or OP |
| Connector on top | Yes |
| Gas regulator compatibility | VK41 series |
| Control system | CVI |
| Direct flame interaction | No |
| Reset button type | Own or external button |
| Reset method | Press own or external button |
| Lockout type | Non-volatile (N) or unstable (V) |
| Blocking mode | Non-volatile or unstable |
| Reset/alarm mode | Integral (I) or remote (R) |
| Electromagnetic filter | Yes |
| Integrated protection | Yes |
| EN 298 compliance | Yes |
| Compatible gas valves | VK4100 series |
| Flame monitoring | Yes |
| Power consumption | 4 W |
| Self-test time | 0 s |
Part numbers
| SKU | S4565AD1017U |
|---|---|
| Additional article | 534.412.127 |
| Model | S4565AD1017 |