Honeywell Gas boiler control unit S4561B1039U(2)
SKU S4561B1039U(2)
Brand Honeywell
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Flame detector type | ionisation |
| Frequency | 50 Hz |
| Power consumption | 10 W |
| Application | used in modern wall-hung boilers |
| Safety standard | EN 298 |
| Spark frequency | 5 Hz |
| Flame power | DT L |
| Gas valve current | 1 A |
| Control type | PCB-type burner control |
| Flame detection method | ionisation |
| Burner type | atmospheric gas burner |
| Spark ignition size | 2.8 mm |
| Flame extinguisher and grounding tip size | 6.3 mm |
| Minimum open spark voltage | 15 kV |
| Safety timer setting | 0 s |
| Self-check time | tcheck |
| Waiting period | tw |
| Safe time | ts |
| PCB dimensions | 105 mm |
| Mounting holes | 4 |
| External reset, alarm, high limit connection | possible |
| Non-volatile blocking | possible |
| Alarm in absence of heat | yes |
| Protective impedance on flame extinguisher | yes |
| Extended spark ignition or quick start | possible |
291.43 EUR
264.94EUR
in stock · 1
incl. 21% VAT · 218.96 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell S4561B1039U(2) is a PCB-type burner control unit designed for automatic ignition and flame supervision of atmospheric gas burners in wall-hung boilers, complying with EN 298. It operates at 220–240 V AC, 50 Hz, with a power consumption of 10 W. The unit uses ionisation flame detection and provides spark ignition at 5 Hz with a minimum open spark voltage of 15 kV. It features a safety timer setting of 0 s, supports external reset and high-limit alarm, and includes non-volatile blocking and alarm in absence of heat. The PCB dimensions are 105 mm with 4 mounting holes, and it fits Pegasus F2/F3 boilers.
Further details
| Application (D) bi or (I) p d | (D) bi or (I) p d |
|---|---|
| Electrical Connection | polyhedral molex 3003 connector compatible with the molex 3001 connector |
| Flame Failure Behavior | go to lockout if a fault is detected |
| Flame indication relay | SPST for SELV circuits or SPDT for line voltage circuits |
| Flame loss sequence | complete sequence of operations after flame loss |
| Ignition Type | both with pilot and direct ignition |
| Ignition capability | up to (G) round, (CL) closed loop or (N) one CL |
| Installation requirement | must be installed outside of access |
| RFI shielding requirement | must be installed in a sufficiently shielded room |
| Recommended installation condition | low ambient temperature and minimal thermal radiation |
| Repair requirement | repair must be carried out by Honeywell |
| Safety Feature | all burner control protection functions are integrated into a reliable system |
| Thermostat connection recommendation | connect upper limit thermostat in series with comfort regulators |
Choosing and fitting
Parts of this type are selected by matching the supply voltage, frequency, and flame detection method (ionisation) to the boiler's control system. The PCB dimensions and mounting hole pattern must align with the boiler's enclosure. The gas valve current rating (up to 1 A) and connector type must be compatible. Always verify the specific model compatibility with the boiler make and model before ordering.
Signs of failure
Common failures include loss of flame detection due to a faulty ionisation probe or wiring, leading to repeated ignition attempts or lockout. Spark ignition may fail if the spark electrode gap is incorrect or the high-voltage cable is damaged. The unit may also fail to start if the safety timer or self-check sequence is interrupted by a faulty sensor or valve. Check for visible damage, loose connections, and correct grounding.
Fits equipment
Pegasus F2 /F3Ferroli Pegasus F2/F3
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Flame detector type | ionisation |
| Frequency | 50 Hz |
| Power consumption | 10 W |
| Application | used in modern wall-hung boilers |
| Safety standard | EN 298 |
| Spark frequency | 5 Hz |
| Flame power | DT L |
| Gas valve current | 1 A |
| Control type | PCB-type burner control |
| Flame detection method | ionisation |
| Burner type | atmospheric gas burner |
| Spark ignition size | 2.8 mm |
| Flame extinguisher and grounding tip size | 6.3 mm |
| Minimum open spark voltage | 15 kV |
| Safety timer setting | 0 s |
| Self-check time | tcheck |
| Waiting period | tw |
| Safe time | ts |
| PCB dimensions | 105 mm |
| Mounting holes | 4 |
| External reset, alarm, high limit connection | possible |
| Non-volatile blocking | possible |
| Alarm in absence of heat | yes |
| Protective impedance on flame extinguisher | yes |
| Extended spark ignition or quick start | possible |
Part numbers
| SKU | S4561B1039U(2) |
|---|---|
| Additional article | 534.412.035 |