ACV printed circuit display 537D3020
SKU 537D3020
Brand ACV
Photos
Key specifications
| Interface type | Screen interface for MCBA controller |
|---|---|
| Application | MCBA-type burner control |
| Electrical connection | Ribbon cable or dedicated header |
| Mounting feature | Screws or snap-in clips |
| Catalogue article numbers | 129.253.003 |
| Compatible control type | MCBA-type burner control |
176.24 EUR
160.22EUR
in stock · 2
incl. 21% VAT · 132.41 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This display module is a screen interface for an MCBA-type burner controller. It receives power and data through a ribbon cable or dedicated header from the control board. It is designed for ACV boilers, including the Compact Condens 35, Prestige 50 Solo MK2, and Heatmaster 70 TC. The module mounts in the front panel using screws or snap-in clips and has article number 129.253.003.
Further details
| Display function | Shows real-time boiler data from the MCBA controller |
|---|---|
| Functions | shows operating status, fault codes, parameter adjustment through keypad |
| Installation safety requirement | Disconnect burner from mains supply before installation; check ribbon cable for damage; ensure connector orientation is correct |
| Mounting | front panel of the burner or boiler cabinet, secured by screws or snap-in clips |
| Mounting location | Front panel of burner or boiler cabinet |
| Power source | Powered through the control board connection |
Choosing and fitting
Displays of this type are selected by matching the manufacturer code and the exact control model; an incorrect display may not communicate, show garbled characters, or fail to indicate lockout codes. They connect to the control board via a ribbon cable or dedicated header and are mounted in the front panel with screws or snap-in clips. Before installation, disconnect the burner from the mains supply and inspect the ribbon cable for damage. Ensure the connector is oriented correctly, as reversed polarity can damage the display or the control board.
Signs of failure
A failed or incompatible display may show garbled characters, fail to illuminate, or unable to communicate with the control board, leaving fault codes unreadable. The burner may operate but technicians and users cannot monitor system status or access diagnostic information. Check the ribbon cable for visible damage and ensure the connector is fully seated and correctly oriented.
Manufacturer documentation
Fits equipment
ACV Prestige 50ACV Compact Condens 35ACV Solo MK2ACV Heatmaster 70 TCACV Prestige 50 Solo MK2ACV HeatMaster 70 TC
ACV Prestige 50 SoloACV MK2 Heatmaster 70 TC
All specifications
| Interface type | Screen interface for MCBA controller |
|---|---|
| Application | MCBA-type burner control |
| Electrical connection | Ribbon cable or dedicated header |
| Mounting feature | Screws or snap-in clips |
| Catalogue article numbers | 129.253.003 |
| Compatible control type | MCBA-type burner control |
Part numbers
| SKU | 537D3020 |
|---|---|
| Additional article | 129.253.003 |