Honeywell Gas valve VK4105M5157U
SKU VK4105M5157U
Model VK4105M5157
Brand Honeywell
Photos
Key specifications
| Regulation of the mixture of gas and air in a ratio of 1 | 1 |
|---|---|
| Safety feature | automatic closing of main valve |
| Operating principle | positive feedback system |
| Two electrical devices | two electrical devices |
| Ignition systems supported | standard DBI ignition systems |
| Adjustment method | gradual adjustment |
| Housing type | standard housing |
| Throttle valve regulation | regulation using a throttle valve |
| Softlite technology | smooth ignition using softlite technology |
| Control type | pressure control by servo drive |
| Control features | electric two-level control mechanism |
| Gas type | natural and liquefied gas |
| Operating position | upright |
| Nominal inlet gas pressure | 25 mbar |
| Diaphragm diameter | 2.8 mm |
| Ambient pressure | 1013 mbar |
| Pressure sensor pipe diameter | 0.5 inch |
| Inlet and outlet diameter | 18.6 mm |
| connection_type | flanged |
| Flanged connections | flanged |
| Built-in filter | fine-mesh filter |
| Filter cleaning | not intended for cleaning |
| Optional output filter | can be installed |
| Mounting feature | holes for mounting |
| Flange collector required | required |
| Pilot gas connection diameter | 4 mm |
| Electrical connection | connector or plug-in rectifier unit |
| Standard DBI ignition systems | standard DBI ignition systems |
| Operating voltage | 24 V |
| Ignition regulator exception | s4565/s4585 series regulators |
| Design features | positive feedback system |
| Pressure servo controller | pressure servo controller |
| Pressure relief valve | pressure relief valve |
| Output pressure stability | stable output pressure |
| Reliability | high reliability |
| Catalogue article numbers | 534.331.080 |
| Flow indication | cubic meters per hour |
183.68 EUR
166.98EUR
in stock · 1
incl. 21% VAT · 138.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
Honeywell VK4105M5157U gas valve is designed for burner control and ignition. It features a standard housing with flanged connections (18.6 mm inlet/outlet), a 2.8 mm diaphragm, a built-in fine-mesh filter, and a 4 mm pilot gas connection. The valve operates on natural and liquefied gas with a nominal inlet pressure of 25 mbar and an ambient pressure of 1013 mbar; output pressure is measured through a 0.5-inch sensor pipe. It employs a positive feedback system, a pressure servo controller, and a pressure relief valve, ensuring automatic main valve closure if power is lost or gas pressure is excessive. Regulation is gradual via a throttle valve, incorporating an electric two-level control mechanism and a 1:1 gas-air mixture ratio. It supports standard DBI ignition systems (excluding S4565/S4585 regulators) and operates at 24 V.
Further details
| Application | control and ignition of the burner |
|---|---|
| Built-in component | vk4105m 5157u gas valve and ignition regulator |
| Closing Variants | b + c, b + b, b + j |
| Ignition Electronics Compatibility | various ignition regulators except S4565/S4585 series |
| Included Components | built-in vk4105m 5157u gas valve and an ignition regulator |
| Measurement setup | pipe with diameter 1/2 inch, 10 times the diameter, through a short hose with length equal to 5 pipe diameters |
| Outlet Orientation | side outlet for main and pilot burners |
| Output pressure stability | stable output pressure even with changes in input pressure |
| Pressure Measuring Fittings | silicone tubes with diameter 4 or 6 mm |
Choosing and fitting
Valves of this type are selected by checking the flange connection size and the pilot gas connection diameter, as well as the closing force variant (e.g., B+C, B+B, B+J). If the valve has a side outlet for main and pilot burners, a flange collector must be used on the burner. Installation requires an upright orientation and the use of the bottom mounting holes. Electrical connections can be made via a connector or a plug-in rectifier unit; operating voltage is typically 24 V.
All specifications
| Regulation of the mixture of gas and air in a ratio of 1 | 1 |
|---|---|
| Safety feature | automatic closing of main valve |
| Operating principle | positive feedback system |
| Two electrical devices | two electrical devices |
| Ignition systems supported | standard DBI ignition systems |
| Adjustment method | gradual adjustment |
| Housing type | standard housing |
| Throttle valve regulation | regulation using a throttle valve |
| Softlite technology | smooth ignition using softlite technology |
| Control type | pressure control by servo drive |
| Control features | electric two-level control mechanism |
| Gas type | natural and liquefied gas |
| Operating position | upright |
| Nominal inlet gas pressure | 25 mbar |
| Diaphragm diameter | 2.8 mm |
| Ambient pressure | 1013 mbar |
| Pressure sensor pipe diameter | 0.5 inch |
| Inlet and outlet diameter | 18.6 mm |
| connection_type | flanged |
| Flanged connections | flanged |
| Built-in filter | fine-mesh filter |
| Filter cleaning | not intended for cleaning |
| Optional output filter | can be installed |
| Mounting feature | holes for mounting |
| Flange collector required | required |
| Pilot gas connection diameter | 4 mm |
| Electrical connection | connector or plug-in rectifier unit |
| Standard DBI ignition systems | standard DBI ignition systems |
| Operating voltage | 24 V |
| Ignition regulator exception | s4565/s4585 series regulators |
| Design features | positive feedback system |
| Pressure servo controller | pressure servo controller |
| Pressure relief valve | pressure relief valve |
| Output pressure stability | stable output pressure |
| Reliability | high reliability |
| Catalogue article numbers | 534.331.080 |
| Flow indication | cubic meters per hour |
Part numbers
| SKU | VK4105M5157U |
|---|---|
| Additional article | 534.331.080 |
| Model | VK4105M5157 |