Honeywell Gas valve VK4115V1204U

SKU VK4115V1204U Model VK4115V1204 Brand Honeywell

Photos

Key specifications

Max. inlet pressure60 mbar
Connection thread3/4" external
Nominal inlet gas pressure25 mbar
Diaphragm diameter2.8 mm
Pilot gas connection diameter4 mm
Inlet and outlet diameter18.6 mm
Leakage requirementsEN 126
Control featureselectric two-level control mechanism
Built-in valveVK4115V1204B gas valve
Operating voltage24 V
Housing typestandard housing
Built-in filterFine-mesh filter
Optional output filterCan be installed
Mounting featureMounting holes at the bottom
Throttle valve regulationRegulation using a throttle valve
Design featurespositive feedback system
Input screenon the input side
Control typepressure control by servo drive
connection_typeflanged connection
Maximum inlet pressure60 mbar
Regulation of the mixture of gas and air in a ratio of 11
Softlite technologySmooth ignition
Compression fitting6 mm
Pressure measuring pointsTop
Outlet Orientationside gas outlet
Pressure sensor pipe diameter0.5 inch
Operating positionupright position
Maximum operating pressure60 mbar
Catalogue article numbers534.322.200
Ambient pressure1013 mbar
Two electrical devicestwo electronic devices
Pressure drop5 mbar
Side socketyes
Pressure servo controllerhigh-tech pressure servo controller
Ignition regulator exceptionexcept s4565/s4585 series regulators
Flanged connectionssuitable for flanged connection
Filter cleaningnot intended for cleaning
Back pressure (1st valve)10 mbar
Pressure feedback nipple diameter6 mm
Gas typeheating, liquefied, natural gas
Flow capacity2.9 m³/h
all specifications (41) ↓
216.27 EUR
196.61EUR
in stock · 2

incl. 21% VAT · 162.49 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This gas valve from Honeywell is designed for burner control and ignition systems. It incorporates a built-in gas valve and ignition regulator, managing gas flow for both pilot and main burners. The valve features a servo-driven pressure control, throttle valve regulation, and an electric two-level control mechanism. It provides smooth ignition through Softlite technology and maintains a 1:1 gas-air mixture ratio. It has a fine-mesh inlet filter, flanged connections, a side gas outlet, and operates at 24 V DC. The valve is suitable for natural gas, liquefied gas, and heating gas.

Further details

Adjustment methodGradual adjustment, adjustable for various control methods
Construction typePressure servo controller and pressure relief valve cooperating
Electrical Connectionconnector or plug-in rectifier unit for DBI ignition systems
Flange Collector Requiredside outlet can only be used with the flange collector of the burner
Ignition electronics compatibilityVarious ignition regulators except S4565/S4585 series
Included Componentsbuilt-in gas valve and specialized ignition regulator
Measurement setupSensor connected to 1/2-inch pipe, 10 times diameter, hose length 5 pipe diameters
Normal Statenormally closed, opens when voltage is applied
Operating PrincipleGas passes through servo controller and opens main valve; maintains constant pressure by regulating main valve
Outlet OrientationSide outlet for main and pilot burners
Output Pressure Stabilitystable output pressure even with changes in input pressure
Pressure Measuring Fittingssilicone tubes with diameter 4 or 6 mm
Pressure Relief Valvehigh-tech pressure servo controller and pressure relief valve
Safety Featureautomatic closing of the main valve in case of lack of power supply or excess gas pressure
Standard Dbi Ignition Systemsplug-in rectifier unit for standard dbi ignition systems

Choosing and fitting

When choosing a replacement of this type, match the connection sizes: the inlet is 3/4" external thread and the outlet is flanged. Confirm the operating voltage (24 V) and that the ignition regulator is not from the excluded S4565/S4585 series. The valve must be installed upright with the bottom mounting holes aligned. If the model has a side gas outlet, the burner must have a flange collector. Connect the pressure feedback nipple with a 6 mm pipe.

All specifications

Max. inlet pressure60 mbar
Connection thread3/4" external
Nominal inlet gas pressure25 mbar
Diaphragm diameter2.8 mm
Pilot gas connection diameter4 mm
Inlet and outlet diameter18.6 mm
Leakage requirementsEN 126
Control featureselectric two-level control mechanism
Built-in valveVK4115V1204B gas valve
Operating voltage24 V
Housing typestandard housing
Built-in filterFine-mesh filter
Optional output filterCan be installed
Mounting featureMounting holes at the bottom
Throttle valve regulationRegulation using a throttle valve
Design featurespositive feedback system
Input screenon the input side
Control typepressure control by servo drive
connection_typeflanged connection
Maximum inlet pressure60 mbar
Regulation of the mixture of gas and air in a ratio of 11
Softlite technologySmooth ignition
Compression fitting6 mm
Pressure measuring pointsTop
Outlet Orientationside gas outlet
Pressure sensor pipe diameter0.5 inch
Operating positionupright position
Maximum operating pressure60 mbar
Catalogue article numbers534.322.200
Ambient pressure1013 mbar
Two electrical devicestwo electronic devices
Pressure drop5 mbar
Side socketyes
Pressure servo controllerhigh-tech pressure servo controller
Ignition regulator exceptionexcept s4565/s4585 series regulators
Flanged connectionssuitable for flanged connection
Filter cleaningnot intended for cleaning
Back pressure (1st valve)10 mbar
Pressure feedback nipple diameter6 mm
Gas typeheating, liquefied, natural gas
Flow capacity2.9 m³/h

Part numbers

SKUVK4115V1204U
Additional article534.322.200
ModelVK4115V1204