Kromschroder Gas solenoid valve VG15R02NT31D 85205030

SKU 85205030 Model VG15R02NT31D Brand Kromschroder

Photos

no photo yet

Key specifications

Nominal diameter (DN)15 mm
Max. inlet pressure200 mbar
Connection threadRp 1/2
Supply voltage230 V
Ingress protectionIP54
Operating temperature-20–60 °C
Fast responsefast opening and fast closing
Durabilitydurable
Safety standardEN 161
Valve typesolenoid gas valve
ProtectionIP54
Automatic gas shut-offyes
Fast openingyes
Fast closingyes
Frequency range50/60 Hz
Connection sizeDN15
Solenoid typeelectromagnetic
Shut-off deviceyes
Automatic gas supply controlautomatic
Heating systemsheating and process systems
Commercial usecommercial
Domestic usedomestic
Original partoriginal valve
German manufacturerKromschroder
Maximum safetyyes
Stable operationstable operation
Durabledurable
Power failure safetyvalve closes in de-energized state
Response timereduced
Control efficiencyimproves gas line control efficiency
Standard sizeDN15
Installation without adaptersyes
Dust resistanceIP54
Boiler room suitableyes
Manufacturer code85205030, 624.331.039
Coil replaceabilityoften replaceable separately
Frequency50 Hz
all specifications (37) ↓
596.16 EUR
541.96EUR
in stock · 3

incl. 21% VAT · 447.90 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Kromschroder VG15R02NT31D is a solenoid gas valve with a nominal diameter of 15 mm (DN15) and a Rp 1/2 connection thread. It operates with a supply voltage of 230 V at 50 Hz and has a maximum inlet pressure of 200 mbar. The valve provides fast opening and closing, and it closes automatically in a de-energized state for safety. It is rated IP54 for dust and splash resistance and operates within a temperature range of -20 to 60 °C. This valve is designed for automatic gas shut-off and control in heating and process systems, suitable for both commercial and domestic use, and complies with EN 161 safety standards.

Further details

Application purposeshut-off device for gas supply control
Certification StandardClass A according to EN 161
Compatibility checkconfirm compatibility with gas type and burner control sequence
Fuel leakage preventionprevents fuel leakage during power failures
Functionshut off and meter gas supply to burner
Gas Typenatural gas, town gas, LPG and air
Gas pressure switch permissiononly when gas pressure switch permits
Industrial useindustrial, commercial and domestic gas installations
Opening commandopen on command from burner control
Premix boiler compatibilitypneumatic gas/air link ties valve to fan
Replacement checkcheck connection size and coil voltage
Safety featurevalve is closed in de-energized state
Suitable fuel typesnatural gas, town gas, LPG, air
Wide operating conditionssuitable for a wide range of operating conditions

Choosing and fitting

When selecting a replacement solenoid gas valve of this type, ensure the connection size (e.g., DN15) and thread type (e.g., Rp 1/2) match the existing piping. Verify the coil voltage (e.g., 230 V) and frequency (e.g., 50/60 Hz) are compatible with the burner control system. Check the maximum inlet pressure rating to suit your gas supply. The valve may be installed directly without adapters if the thread matches. The coil is often replaceable separately, so confirm its specifications if only the coil needs replacement.

Signs of failure

Common failure modes for solenoid gas valves include coil burnout, which may be caused by incorrect supply voltage or electrical faults, leading to the valve not opening. A leaking seat can cause gas to pass when the valve should be closed, potentially resulting in unsafe operation. Drifting outlet pressure may indicate a worn servo regulator or seized mechanism. If the valve fails to open or close properly, check the electrical connections, coil resistance, and for debris or damage on the seat.

All specifications

Nominal diameter (DN)15 mm
Max. inlet pressure200 mbar
Connection threadRp 1/2
Supply voltage230 V
Ingress protectionIP54
Operating temperature-20–60 °C
Fast responsefast opening and fast closing
Durabilitydurable
Safety standardEN 161
Valve typesolenoid gas valve
ProtectionIP54
Automatic gas shut-offyes
Fast openingyes
Fast closingyes
Frequency range50/60 Hz
Connection sizeDN15
Solenoid typeelectromagnetic
Shut-off deviceyes
Automatic gas supply controlautomatic
Heating systemsheating and process systems
Commercial usecommercial
Domestic usedomestic
Original partoriginal valve
German manufacturerKromschroder
Maximum safetyyes
Stable operationstable operation
Durabledurable
Power failure safetyvalve closes in de-energized state
Response timereduced
Control efficiencyimproves gas line control efficiency
Standard sizeDN15
Installation without adaptersyes
Dust resistanceIP54
Boiler room suitableyes
Manufacturer code85205030, 624.331.039
Coil replaceabilityoften replaceable separately
Frequency50 Hz

Part numbers

SKU85205030
Additional article624.331.039
ModelVG15R02NT31D