Brahma Ignition transformer T11/A 15060001
SKU 15060001
Model T11/A
Brand Brahma
Photos
Key specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 9 kV |
| Poles / outlets | 1 |
| Length | 150 mm |
| Width | 101 mm |
| Height | 100 mm |
| Construction type | shell-type core |
| Secondary insulation | polyester resin |
| Ignition voltage | 15–15 kV |
| Electromagnetic interference protection | radio interference suppression shield |
| Catalogue article numbers | 246.820.086 |
| Ingress protection | IP00 |
| Mounting feature | any position |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 550 mm |
| Fuel | liquid or gaseous fuel |
| Application | liquid or gaseous fuel burners |
| Secondary grounding | central |
| Insulator material | 30% PBT glass fiber |
| Secondary current | 20 mA |
| Duty cycle | 33% in 3 minutes |
| Net weight | 2 kg |
| Power consumption | 240 W |
| Frequency | 50 Hz |
251.50 EUR
228.64EUR
in stock · 2
incl. 21% VAT · 188.96 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This ignition transformer is intended for liquid or gaseous fuel burners. It operates at 220 V, 50 Hz, consuming 240 W. The secondary output is 9 kV at 20 mA, with a peak ignition voltage of 15 kV. It has a shell-type core, polyester resin insulation, and a radio interference suppression shield. Its dimensions are 150 x 101 x 100 mm, net weight 2 kg, and protection class IP00. The recommended spark gap is 3–5 mm, and the cable length is 550 mm.
Further details
| Fire-retardant caps | caps painted with fire-retardant paint covering coils |
|---|---|
| RF shield grounding | must be connected to a reliable ground |
Choosing and fitting
When choosing a replacement of this type, verify that the supply voltage, frequency, output voltage and current, and duty cycle match the burner's requirements. The mounting system may vary between models; the part reference often includes a letter designating the mounting arrangement. Also confirm the type of high-voltage connection (screw terminal or cylindrical plug). Installation can be in any position. Ensure the transformer is grounded and that the ignition cable is kept as short as possible.
All specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 9 kV |
| Poles / outlets | 1 |
| Length | 150 mm |
| Width | 101 mm |
| Height | 100 mm |
| Construction type | shell-type core |
| Secondary insulation | polyester resin |
| Ignition voltage | 15–15 kV |
| Electromagnetic interference protection | radio interference suppression shield |
| Catalogue article numbers | 246.820.086 |
| Ingress protection | IP00 |
| Mounting feature | any position |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 550 mm |
| Fuel | liquid or gaseous fuel |
| Application | liquid or gaseous fuel burners |
| Secondary grounding | central |
| Insulator material | 30% PBT glass fiber |
| Secondary current | 20 mA |
| Duty cycle | 33% in 3 minutes |
| Net weight | 2 kg |
| Power consumption | 240 W |
| Frequency | 50 Hz |
Part numbers
| SKU | 15060001 |
|---|---|
| Additional article | 246.820.086 |
| Model | T11/A |