Key specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 9 kV |
| Poles / outlets | 1 |
| Length | 110 mm |
| Width | 96 mm |
| Height | 78 mm |
| Body material | polyester resin |
| Construction type | shell shape |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 550 mm |
| Protection class (IP) | IP00 |
| Electrical insulation | polyester resin |
| Insulator material | 30% PBT glass fiber |
| Secondary grounding | grounded secondary windings |
| Electromagnetic interference protection | shield for suppressing radio interference |
| Input effective current | 1.1 |
| High discharge power | high discharge power |
| High efficiency | high efficiency and ignition power |
| Default connection insulator | screw terminal |
| Mounting systems variety | various mounting systems |
| Two caps | two caps |
| Shape | shell shape |
| Weight | 2 g |
| Dimensions | 11x9.6x7.8 |
| Number of poles | 1 |
| Peak voltage | 1 kV |
| High voltage insulation | high insulation and durability |
| Durability | high insulation and durability |
| Reliable ignition | reliable and efficient ignition process |
| Secondary current | 20 mA |
| Duty cycle | 33% in 3 minutes |
| Net weight | 2 kg |
| Power consumption | 240 W |
| Frequency | 50 Hz |
237.18 EUR
215.62EUR
in stock · 2
incl. 21% VAT · 178.20 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma T11/N ignition transformer (SKU 15099001) is a shell-shaped component designed for burners operating on liquid or gaseous fuels. It operates at a supply voltage of 220 V and 50 Hz, with a secondary voltage of 9 kV and a secondary current of 20 mA. The transformer has a power consumption of 240 W, an input effective current of 1.1 A, and a duty cycle of 33% in 3 minutes. It features grounded secondary windings, a shield for suppressing radio interference, and two caps. The body is made of polyester resin, and the insulator material is 30% PBT glass fiber. The recommended spark distance is 3–5 mm, and the standard power cable length is 550 mm. The transformer weighs 2 kg and has dimensions of 110 mm x 96 mm x 78 mm.
Further details
| Application scope | designed for use with burners running on both liquid and gaseous fuels |
|---|---|
| Connection insulator types | screw and cylindrical (4 mm or 6.3 mm) |
| Flexibility in installation | variety of connection and mounting systems, providing flexibility in installation |
| Ideal for wide range | ideal choice for a wide range of applications |
| Identification letter | letter of the alphabet for the mounting system |
| Suitable for long ignition wires | particularly suitable for applications where long ignition wires are required |
| Versatility | versatility and ability to provide ignition in systems using a variety of fuels |
Choosing and fitting
When selecting an ignition transformer of this type, ensure the supply voltage, frequency, and secondary voltage/current ratings match the burner's requirements. The mounting system must be compatible with the burner's design; these transformers may have different mounting forms, so verify the physical dimensions and mounting hole patterns. The connection insulator type (screw or cylindrical) should be checked against the existing wiring. Measure the available space and compare with the transformer's dimensions to ensure a proper fit.
Signs of failure
Common failure modes for ignition transformers include internal short circuits, open windings, or insulation breakdown, which can result in weak or no spark at the electrodes. Symptoms may include the burner failing to ignite, intermittent ignition, or a buzzing sound from the transformer. Check for visible damage, carbon tracking, or overheating. Measure the secondary voltage with a suitable high-voltage probe to confirm output; if it is significantly below spec, the transformer likely needs replacement.
All specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 9 kV |
| Poles / outlets | 1 |
| Length | 110 mm |
| Width | 96 mm |
| Height | 78 mm |
| Body material | polyester resin |
| Construction type | shell shape |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 550 mm |
| Protection class (IP) | IP00 |
| Electrical insulation | polyester resin |
| Insulator material | 30% PBT glass fiber |
| Secondary grounding | grounded secondary windings |
| Electromagnetic interference protection | shield for suppressing radio interference |
| Input effective current | 1.1 |
| High discharge power | high discharge power |
| High efficiency | high efficiency and ignition power |
| Default connection insulator | screw terminal |
| Mounting systems variety | various mounting systems |
| Two caps | two caps |
| Shape | shell shape |
| Weight | 2 g |
| Dimensions | 11x9.6x7.8 |
| Number of poles | 1 |
| Peak voltage | 1 kV |
| High voltage insulation | high insulation and durability |
| Durability | high insulation and durability |
| Reliable ignition | reliable and efficient ignition process |
| Secondary current | 20 mA |
| Duty cycle | 33% in 3 minutes |
| Net weight | 2 kg |
| Power consumption | 240 W |
| Frequency | 50 Hz |