Brahma Ignition transformer TC1SVCA 15911051
SKU 15911051
Model TC1SVCA
Brand Brahma
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 15 kV |
| Poles / outlets | 1 |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Operating temperature | -10–60 °C |
| Peak current (mA) | 45 mA |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 560 mm |
| Output voltage frequency | 6–10 kHz |
| Peak voltage | 15 kV |
| Number of contacts | 1 |
| Secondary current | 45 mA |
| Duty cycle | 100% |
| Net weight | 0.42 kg |
| Power consumption | 25 W |
| Frequency | 50–60 Hz |
| Ambient temperature, max | 60 °C |
67.88 EUR
61.71EUR
in stock · 2
incl. 21% VAT · 51.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma TC1SVCA ignition transformer, SKU 15911051, is a compact electronic device designed for burner ignition in gas and liquid fuel systems. It operates on a 220–240 V supply at 50–60 Hz, consuming 25 W, and generates a peak secondary voltage of 15 kV with a secondary current of 45 mA. The transformer features a 100% duty cycle, allowing continuous operation, and is rated for ambient temperatures from -10 to 60 °C. It has one high-voltage contact and supports an ignition cable up to 1.5 m in length, with a standard power cable of 560 mm. The recommended spark distance is 3–5 mm, and the output voltage frequency ranges from 6 to 10 kHz. The unit weighs 0.42 kg net.
Choosing and fitting
When selecting a replacement ignition transformer of this type, verify that the supply voltage, frequency, and power consumption match the burner's electrical specifications. Ensure the secondary voltage and current are compatible with the ignition electrode and cable length. Check the number of high-voltage contacts (single or double) and the mounting configuration to fit the burner's design. Measure the physical dimensions and compare with the existing unit to confirm proper fitment. Also, confirm the duty cycle requirement (continuous or intermittent) and the operating temperature range for your application.
Signs of failure
Common failure modes for ignition transformers include internal short circuits, open windings, or breakdown of insulation, leading to weak or no spark. Symptoms may include the burner failing to ignite, intermittent ignition, or a buzzing sound from the transformer. Check for visible damage, overheating, or carbon tracking on the high-voltage output. Verify the input voltage and continuity of the primary and secondary windings with a multimeter. Also, inspect the ignition cable and electrode for wear or improper gap, as these can cause excessive load and premature failure.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 15 kV |
| Poles / outlets | 1 |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Operating temperature | -10–60 °C |
| Peak current (mA) | 45 mA |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 560 mm |
| Output voltage frequency | 6–10 kHz |
| Peak voltage | 15 kV |
| Number of contacts | 1 |
| Secondary current | 45 mA |
| Duty cycle | 100% |
| Net weight | 0.42 kg |
| Power consumption | 25 W |
| Frequency | 50–60 Hz |
| Ambient temperature, max | 60 °C |
Part numbers
| SKU | 15911051 |
|---|---|
| Additional article | 246.820.109 |
| Model | TC1SVCA |